User Manual - Version 2.2 Manual

Counterpart User Manual - Installation 9
2.6 Wire Specifics
Wires connecting to J1, J2, J3, or J4 should adhere to the following specifications:
2.7 Cable Grounding
Except for the power cord, all cables should be grounded against the scale enclosure. Do the following to ground
shielded cables.
Use the lockwashers, clamps, and kep nuts provided in the parts kit to
install grounding clamps on the
enclosure studs. Install grounding clamps that will be used; do not tighten nuts.
Route cables and grounding clamps to determine cable lengths require
d to reach cable connectors. Mark
cables to remove insulation and shield as described below:
For cables with foil shielding, strip insulation and
foil from the cable half an inch (15 mm) past the
grounding clamp (see Figure 2-4). Fold the foil shield back on the cable where the cable passes through
the clamp. Ensure silver (conductive) side of foil is turned outward for contact with the grounding clamp.
For cables with braided shielding, strip cable insulatio
n and braided shield from a point just past the
grounding clamp. Strip another half inch (15 mm) of insulation only to expose the braid where the cable
passes through the clamp (see Figure 2-4 on page 9).
Finish installation using cable mounts and ties to secure ca
bles inside of indicator enclosure.
Figure 2-4. Grounding Clamp Attachment for Foil-Shielded and Braided Cabling
2.7.1 Serial Communications
Wire the serial communications cables to J4, which is Port 2 (5-wire RS-232 port). J5 is Port 1 (RS-232 and 20
mA). Connect communications cables to J5 and J4 as shown in Table 2-3.
Use cable ties to secure serial cables to
the inside of the enclosure.
Port 1 supports full duplex RS-232 communications only; Port
2 provides either active 20 mA output or duplex
RS-232 transmission. Both ports are configured using the SERIAL menu. See Section 3.6.5 on page 36.
Wire Range Wire Strip Length
28~12 AWG stranded or solid wire 5~6 mm (3/16” ~ 1/4”)
Table 2-2. Wire Specifications for Connectors
Connector Pin Signal Port
J4
1 +20 mA
2
2 Ground or
-20 mA
3 Tx
4 Rx
5 CTS
6 RTS
$PSEHSJQ