User Manual - Version 2.2 Manual
Counterpart User Manual - Installation 9
2.6 Wire Specifics
Wires connecting to J1, J2, J3, or J4 should adhere to the following specifications:
2.7 Cable Grounding
Except for the power cord, all cables should be grounded against the scale enclosure. Do the following to ground
shielded cables.
• Use the lockwashers, clamps, and kep nuts provided in the parts kit to
install grounding clamps on the
enclosure studs. Install grounding clamps that will be used; do not tighten nuts.
• Route cables and grounding clamps to determine cable lengths require
d to reach cable connectors. Mark
cables to remove insulation and shield as described below:
• For cables with foil shielding, strip insulation and
foil from the cable half an inch (15 mm) past the
grounding clamp (see Figure 2-4). Fold the foil shield back on the cable where the cable passes through
the clamp. Ensure silver (conductive) side of foil is turned outward for contact with the grounding clamp.
• For cables with braided shielding, strip cable insulatio
n and braided shield from a point just past the
grounding clamp. Strip another half inch (15 mm) of insulation only to expose the braid where the cable
passes through the clamp (see Figure 2-4 on page 9).
• Finish installation using cable mounts and ties to secure ca
bles inside of indicator enclosure.
Figure 2-4. Grounding Clamp Attachment for Foil-Shielded and Braided Cabling
2.7.1 Serial Communications
Wire the serial communications cables to J4, which is Port 2 (5-wire RS-232 port). J5 is Port 1 (RS-232 and 20
mA). Connect communications cables to J5 and J4 as shown in Table 2-3.
Use cable ties to secure serial cables to
the inside of the enclosure.
Port 1 supports full duplex RS-232 communications only; Port
2 provides either active 20 mA output or duplex
RS-232 transmission. Both ports are configured using the SERIAL menu. See Section 3.6.5 on page 36.
Wire Range Wire Strip Length
28~12 AWG stranded or solid wire 5~6 mm (3/16” ~ 1/4”)
Table 2-2. Wire Specifications for Connectors
Connector Pin Signal Port
J4
1 +20 mA
2
2 Ground or
-20 mA
3 Tx
4 Rx
5 CTS
6 RTS
$PSEHSJQ
*OTVMBUFEDBCMF
'PJMTJMWFSTJEFPVU
(SPVOEJOHDMBNQ
4IJFMEXJSFDVU
-FOHUIPGGPJMCFGPSFGPMEJOH
CBDLPODBCMFJOTVMBUJPO
$VUJOTVMBUJPOIFSF
GPSGPJMTIJFMEFEDBCMFT
#SBJE
$VUJOTVMBUJPOIFSF
GPSCSBJEFEDBCMFT
/05&*OTUBMMMPDLXBTIFST
mSTUBHBJOTUFODMPTVSF
VOEFSHSPVOEJOHDMBNQ