User Manual - Version 2.2 Manual

30 Counterpart User Manual
RECALL ON
OFF
ON allows the Tare, Zero, and Units values to be maintained across a power cycle. Over/
Under/Target/ID values are also maintained.
OFF clears the values on a power cycle. Zero is r
eset to calibrated zero and Units are reset to
Primary. Over/Under/Target/ID values are reset as well.
DISPLAY CONTRAST
BRIGHT
IMAGE
Adjusts Counterpart display viewi
ng. Key in a value
BRIGHT - Key in a value
IMAGE - enter negative or positive
KEYBEEP OFF
ON
Select ON to alert the user every time a key is pressed.
TOTAL OFF
ON
Totalization mode check
Level 4 submenus - under the Level 3 Count Feature
NEGCOUNT ON
OFF
Sets whether negative weighing mode is off or on.
SAMPLQTY 10
25
50
100
Is the default value for sample quantity.
INSFSMPLE 0.1
0.2
0.0
A minimum sample size is required based on the
platform capacity and product weight.
LOTUPDT OFF
ON
OFF - Changing or deleting the lot value in operat
ion mode does not update the stored copy
of the currently loaded ID record.
ON - Changing or deleting the lot value in operation mode
saves the changes into the stored
copy of the currently loaded ID record.
SCLCHG REZERO
CHKSTABLE
XFRTARE
XFRUTWT
Scale change. These are actions taken when
changing from one scale to another.
See Level 5 submenu.
NEWITEM OFF
ON
New item. This prompts to add an ID to memory when an unknown
ID is requested from
weigh mode.
XFRSMPL OFF
ON
After sample. After a sample, a switch is done fr
om the current scale to the next scale that is
larger than or equal to the current scale. If a sample is done on the largest of the scales, a
switch will not be done.
DISPACC OFF
ON
Display accuracy
FEATUR Menu
Parameter Choices Description
Table 3-5. FEATUR Submenu Parameters (Continued)