User Manual - Version 2.2 Manual

Counterpart User Manual - Configuration 31
UTWTUPDT OFF
ON
Enables or disables the updating of the loaded ID with a new unit weight value.
OFF - Parts can be sampled (generat
ing a new unit weight) or a unit weight can be keyed or
scanned but the new unit weight is not saved into the stored copy of the currently loaded ID
record.
ON - If on, the unit weight will update the stored value whether at zero or actual value.
UTWTBASE 1000
1
Unit weight base. 1=APW (Average Piece W
eight), 1000=Piece weight per thousand.
DISPMODE COUNT
WEIGHT
UNITWEIGHT
Display mode. This chooses the value to be displayed as large in viewing window.
Level 4 submenus - under the Level 3 Region Feature
REGULA NTEP
CANADA
INDUST
NONE
OIML
Regulatory mode. Specifies the regulatory agency having j
urisdiction over the scale site.
The value specified for REGULA affects the function of the fr
ont panel TARE and
ZERO keys.
OIML, NTEP, and CANADA modes allow a tare
to be acquired at any weight greater
than zero. NONE allows tares to be acquired at any weight value.
OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight
is at no load. NONE allows tares to be cleared at any weight value.
NTEP and OIML modes allow a new tare to be acquired even if a tare is already
present. In CANADA mode, the previous tare must be cleared before a new tare can
be acquired.
NONE, NTEP and CANADA modes allo
w the scale to be zeroed in either gross or net
mode as long as the current weight is within the specified ZRANGE. In OIML mode,
the scale must be in gross mode before it can be zeroed; pressing the ZERO key in
net mode clears the tare.
INDUST provides a set of subparameters to allow customization of tare, clear, and
print functions in non-legal-for-trade scale installations.
When in Legal-for-Trade mode, refer to Section 9.9.1 on page xx for more information on
using this feature.
REGWOR GROSS
BRUTTO
Sets the term printed when weighing in gross mode. Selecting BRUTTO replaces Gros
s with
Brutto.
DECFMT DOT
COMMA
Specifies whether decimal numbers are displayed
using a period (DOT) or a comma.
TIME TFORMT
T SEP
Allows you to set the current time, and the time
format and separator character.
DATE DFORMT
D SEP
Allows you to set the current date, and date form
at and date separator character.
Level 4 submenus - under the Level 3 Consec # Feature
CURVAL 0 This is the starting number.
RESVAL 0
This is the ending/reset value.
Level 4 submenus - under the Level 3 Password Feature
FEATUR Menu
Parameter Choices Description
Table 3-5. FEATUR Submenu Parameters (Continued)
Note