User Manual - Version 2.2 Manual

34 Counterpart User Manual
3.6.4 FEATUR Menu, REGULA / INDUST Submenu
Figure 3-9. FEATUR Menu, REGULA/INDUST Submenu
FEATUR Menu, REGULA / INDUST Submenu
Parameter Choices Description
LEVEL 6, REGULA / INDUST submenu
SNPSHT DISPLY
SCALE
Display or Scale weight source.
ZTARE NO
YES
Remove tare on ZERO.
KTARE YES
NO
Always allow keyed tare.
MTARE REPLAC
REMOVE
NOTHIN
Multiple tare action.
NTARE NO
YES
Allow negative or zero tare.
CTARE YES
NO
Allow CLEAR key to clear tare/accumulator.
PRTMOT NO
YES
Allow print while in motion.
PRTPT NO
YES
Add PT to keyed tare print.
OVRBAS CALIB
SCALE
Zero base for overload calculation.
CALIB = Calibrate Zero
SCALE = Scale Zero
Table 3-6. REGULA / INDUST Submenu Parameters
REGULAT
SNPSHT
DISPLY
INDUST
SCALE
NO
YES
ZTARE KTARE
YES
NO
MTARE
REMOVE
REPLAC
NOTHN
NTARE
YES
NO
CTARE
PRTMOT
NO
YES
PRTPT
NO
YES
CALIB
SCALE
AGENCYOVRBAS
SCALES FEATUR PFORMT
SERIAL
REGION
NTEP
INDUST
NONE
OIML
CANADA
XXXXXXX
ID
DISPLAYTESTSETUPAUDIT CALIBR
COUNT
CONFIG
Only displayed if INDUST is selected
from the REGULAT parameter
UID
CONSC#
PASSWD
SOFTKEYS
KEYLCK STNDBY
RECALL
REGWOR DECFMT TIME DATE
ETHERNET
Scale Parameter Levels
Level 1
Level 2
Level 3
NO
YES
VERSDIGIOSETPTS
DISPLAY KEYBEEP
TOTAL
SETPTS