User Manual - Version 2.2 Manual

Counterpart User Manual - Configuration 35
AGENCY NTEP
CANADA
INDUST
NONE
OIML
Selects the agency having jurisdiction
over the scale site.
OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight
gr
eater than zero. NONE allows tares to be acquired at any weight value. A
tare can be cleared only if the gross weight is at no load. NONE allows tares
to be cleared at any weight value.
NTEP and OIML modes allow a new tare to be acquired even if a tare is
alr
eady present. In OIML mode, printing is not allowed if the scale is more
than -20dd.
In CANADA mode, the previous tare must be cleared before a new tare can
be acquired.
NONE, NTEP and CANADA modes allow the
scale to be zeroed in either
gross or net mode as long as the current weight is within the specified
ZRANGE. In OIML mode, the scale must be in gross mode before it can be
zeroed; pressing ZERO in net mode clears the tare.
INDUST provides a set of subparameters to allow customization of tare,
clear, and print functions in non-legal-for-trade applications.
The value specified for this parameter affects the function of the front panel TARE and
ZERO keys. See Section 9.9 on page 86 for more information.
When in Legal-for-Trade mode, refer to Section 9.9.1 on page xx for more information
on using this feature.
FEATUR Menu, REGULA / INDUST Submenu
Parameter Choices Description
LEVEL 6, REGULA / INDUST submenu
Table 3-6. REGULA / INDUST Submenu Parameters (Continued)