User Manual - Version 2.2 Manual

Counterpart User Manual - Scale Operations 61
5.8 Parts Reduction Counts
Parts reduction can also be done by using the - key while the scale is in the weighing mode and the memory
annunciator is on.
1. Conduct a sampling process to determine
the unit weight of the pieces. Or key in a known weight or
recall an ID.
2. Enter known tare weight, or place an empty container on th
e scale to perform tare function. If ID was
recalled in step one its tare value is already loaded.
3. Place container (full of parts) on the scale. The number of piece
s in the container is shown in the ”PCS”
area of the display.
4. Press the
Total + softkey to store the number of pieces in the container. The memory (M) icon is shown.
The net weight of the items in the container is stored and the totalization count is incremented. The total
piece count value is shown in place of the piece weight value and will be labeled
”ttl”. The total net weight
is shown in place of the normal ID Code: line - it is labeled as Total Weight.
5. Remove the number of parts required from
the container and press the Total - softkey. The total piece
count value is now equal to the number of pieces removed. The number of pieces remaining in the
container is shown in the
Pcs area of the display. The total weight is now equal to the weight of the
removed pieces.
6. Repeat step 5 as needed.
Once part reduction has been started, a press of Total + will give you an error message.
5.9 Accumulate Feature For Weight
The accumulate feature allows a weight value to be accumulated. Use the following steps to use this feature.
1. Enable the Accumulate in the Scale Menu. Press the
On key and the display will say Accumulator Enabled.
2. Set up the Display Accum - (DSP ACC) and Swap Display (SWAPDSP) softkey. Refer to Section 1.7 of the
manual for help on setting up softkeys.
3. The weight must be active on the display.
4. Each time there is a print, the weight value is added to
the accum register and keeps track of how many
accums were completed. Product must be removed from the platform and the display returned to zero
each time this is done.
5.9.1 Printing the Accumulated Total
Press the Print key to print the accumulated total when the Accum Value is displayed.
5.9.2 Clearing the Accumulated Total
1. Push the CLR softkey when the display Accum has been pressed.
2.
PRESS CLEAR TO VERIFY, is displayed. Press CLR again to clear the accum value.
Note