User Manual - Version 2.2 Manual

66 Counterpart User Manual
SC.WLIN.V1
SC.WLIN.V5#n
Test weight value for linearization points
1–5
0.000001–9999999
SC.WLIN.C1–
SC.WLIN.C5#n
Calibrate linearization points 1–5
SC.LC.CD#n Deadload coefficient
SC.LC.CW#n Span coefficient
SC.LC.CZ#n Temporary zero
SC.REZERO#n Rezero
SC.SEC#n Secondary units lb, kg, g, oz, OFF
SC.TER#n Tertiary units
lb, kg, g, oz, OFF
Command Description Values
Table 6-4. SCALES Serial Commands (Continued)
Command Description Values
EDP.BAUD#p Port baud rate 1200, 2400, 4800, 9600, 19200, 28800, 38400, 57600, 115200
EDP.BITS#p Port data bits/parity 8NONE, 7EVEN, 7ODD
EDP.STOPBITS#p Port stop bits 1, 2
EDP.PRNMSG#p Print message ON, OFF
EDP.ECHO#p Port echo ON, OFF
EDP.EOLDLY#p Port end-of-line delay 0–255 (0.1-second
intervals)
EDP.HEADERS#p Port header ON, OFF
EDP.INPUT#p Port input PORT 1 - CMD, SCANNER, SCALE, IND SC
PORT 2 - CMD, SCANNER
PORT 3 - CMD, SCANNER, KEYBOARD
EDP.PORT Port reporting command. It responds to the port you are connected to.
EDP.RESPONSE#p Port response ON, OFF
EDP.SOURCE#p Port source 1, 2, 3
EDP.STREAM#p Port stream OFF, LFT, INDUST
EDP.TERMIN#p Port termination CR/LF, CR
STR.POS#p Custom stream identifiers None, Space, +
STR.NEG#p None, Space, -
STR.PRI#p 8 alphanumeric characters
STR.SEC#p
STR.TER#p
STR.GROSS#p
STR.NET#p
STR.TARE#p
STR.MOTION#p 2 alphanumeric characters
STR.RANGE#p
STR.OK#p
STR.INVALID#p
STR.ZERO#p
Table 6-5. SERIAL Port Serial Commands