MSI9750A RF Remote Weight Indicator Operator’s Manual
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE Th is Pa ge In te nt io na lly Le ft Bl a nk ® Page 2 MSI-9750A RF Remote Indicator • User Guide
MEASUREMENT SYSTEMS INTERNATIONAL TABLE OF CONTENTS SECTION 1 – INTRODUCTION & ORIENTATION ................................4 Introduction .........................................................................4 9750A Keyboard .................................................................4 Key Descriptions .................................................................5 9750A Display Symbols......................................................6 General Information .................................
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE SECTION 1 – INTRODUCTION & ORIENTATION INTRODUCTION ® The Measurement Systems International MSI-9750A RF Remote Indicator is an accessory component of MSI's CellScale® System. Combined with 1 or more CellScales, the 9750A provides complete control over all scale and data functions. The 9750A serves as a remote terminal for any CellScale and has no internal measurement capability.
MEASUREMENT SYSTEMS INTERNATIONAL KEY DESCRIPTIONS POWER The POWER key turns the 9750A On and Off. The POWER key must be held for 1 second to ensure startup. ZERO The ZERO key is used to zero out residual weight on the scale. When entering numbers or strings the ZERO key is used to Clear (delete) characters. CLR 0 T TARE T The TARE key is used to zero out the weight of containers, trucks, or carriers and to place the scale in the Net weight mode.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE 9750A DISPLAY SYMBOLS The 9750A uses a full dot matrix graphics display which allows 3 sizes of fonts and full use of graphic symbols. On standard single channel and multi-channel displays, certain symbols are used for scale specific indications. ® ~ O ∑ GRS The motion symbol indicates that the weight has not settled within the motion window (usually ±1d). While this symbol is illuminated, the scale will not zero, tare, or totalize.
MEASUREMENT SYSTEMS INTERNATIONAL GENERAL INFORMATION The 9750A is a versatile indicator capable of displaying many data items. As a member of the CellScale family the 9750A does not stand alone. It is a slave device to a MSI-9000 CellScale. All data displayed on the 9750A is received via RF from a master CellScale. Many menus in the 9750A depend on information from the CellScale. Therefore, turn the CellScale on before using the 9750A.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE FEATURES • Designed to meet or exceed all US and international standards. • Multiple Customized Display Modes, single channel or multiple channel modes ® • Each 9750A can act as a terminal for any CellScale. A 9750A can monitor multiple scale channels on a single CellScale, or multiple scales tied to multiple CellScales. • • • • • • • • • • Reliable 2.4 GHz Frequency Hopping RF communications. Highly immune to interference and multi-path problems.
MEASUREMENT SYSTEMS INTERNATIONAL THE CELLSCALE FAMILY 1) Model 9000 CellScale – Rugged unit for interfacing any scale and converting it to RF networking. 2) Model 9008 Multiplexer – Allows up to eight scales with independent calibrations, to share a single CellScale input channel. 3) Model 9020 CellModem – For interfacing peripheral devices to a CellScale. 4) Model 3750CS – Fixed mount indicator for CellScales. Capable of control and calibration.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE UNIT SETUP The 9750A is simple to setup and use. If there are no peripheral devices such as a printer or bar code scanner, setup consists of charging the battery, and setting the modem controls to talk to a 9000 CellScale. ® BATTERY The 9750A uses a high capacity Nickel Metal Hydride Rechargeable battery pack. The battery pack will power the 9750A for up to 8 hours depending mainly on how much the LCD backlight is on.
MEASUREMENT SYSTEMS INTERNATIONAL SECTION 2 – RF SCALE COMMUNICATIONS The 9750A is a component of the MSI CellScale System. The CellScale system uses frequency hopping spread-spectrum RF Modem technology transmitting in the 2.4 GHz ISM band. RF Modems have been problematic as the RF bands are very hostile, corrupted by noise, path loss and interfering transmission from other radios.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE RF NETWORK SETUP The 9750A is a RF Modem connected device. The RF Modem requires setup to connect to one or more CellScales. The 9750A stores information for all 64 possible networks. Each network setting can be modified with the “Modem ® Settings Menu”. MODEM SETTINGS SETTINGS v2.05 v2.
MEASUREMENT SYSTEMS INTERNATIONAL ADVANCED MODEM SETTINGS The “ADVANCED SETTINGS’ menu provides access to some of the advanced features of the 9750A’s RF Modem. These features are not usually needed and should be left to defaults. ADVANCED SETTINGS 1 Lock Out Key Ø 2 802.11 Avoid OFF 3 Scan Network OFF 4 Reranging 652.7 sec LOCK OUT KEY ESC exits no change ENTER saves value Ø-9 replaces value Signal Strength 13Ø Modem Ser.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE CONFIGURING FOR MULTIPLE NETWORKS The 9750A can access multiple CellScales by switching Networks. A press of the ADDRESS key will change the network allowing the 9750A to monitor and control different scales. Because each CellScale has both a network ® and a CS address, these must be set up with the “SETUP RF NETWORK” menu and made active. The 9750A can access up to 64 CellScale based Networks.
MEASUREMENT SYSTEMS INTERNATIONAL Transmit power set to HI. Time out set to 10 seconds. My Address remains unchanged and is the same in any network. TROUBLESHOOTING RF CONNECTION PROBLEMS Most connection problems are caused by improperly set up RF Networks. Both the 9750A and the master CellScale unit must have identical Network numbers. In addition, the CS Address must match on both units.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE RF SITE TESTING The 9750A provides a means to check the efficiency of RF transmissions using the RF Site Testing function. Program a function key (use the procedure in Section 4) to “RF Site Testing” to run the test. ® 1) Place the 9750A in close proximity of the master CellScale unit. Make sure communications are good (weight is on the display, all data types have been reported). 2) Press the function key programmed for “RF Site Testing”.
MEASUREMENT SYSTEMS INTERNATIONAL SECTION 3 – SCALE OPERATION POWER To Turn On the Power 1) Press and hold POWER for 1 second. The display should light and show the MSI Logo. 2) The LCD then displays “MSI-9750A-5”, the Network currently loaded as the active Address, and the software version number. The display will read “Searching Add XX” while establishing communications with the master CellScale. 3) Next the RF network is contacted.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE TO SELECT THE DISPLAY CHANNEL As mentioned above, the 9750A will access any channels setup in the CellScale. It does this with the “CHANNEL” function. Use the CHANNEL key to step from channel to channel as dictated by the Scan list stored in the CellScale. If the CellScale has only one scale channel defined, only® 1 display mode is necessary. This is usually the case for MSI-6260CS, MSI-9300 Crane Scales, and other single load cell systems.
MEASUREMENT SYSTEMS INTERNATIONAL To Switch Between Multi-Channel Display and Single Channel Displays 1) Highlight the channel you wish to see in the single channel mode by pressing the UP (^) or DOWN (v) cursor keys. 2) Once highlighted press DISPLAY. The highlighted channel will appear in the single channel mode. 3) Perform any scale function while in the single channel mode. 4) To return to the multi-channel display, press DISPLAY.
9750A 3) HANDHELD RF REMOTE INDICATOR for CELLSCALE the scale will zero. The scale will accept a zero setting over the full Range of the scale (NTEP and other Legal-for-trade models may have a limited zero range). Zero settings above 4% of full scale will subtract from the overall capacity of the scale. For example if you zero out 100 lb. on a 1000 lb. scale the overall capacity of the scale will reduce to 900 lb. plus ® the allowed over-range amount.
MEASUREMENT SYSTEMS INTERNATIONAL Multiple Tare Memories The 9750A is capable of storing Tare values through the use of the ID Codes. Each ID code stores an independent Tare. See Section 3 “ID Codes” for more information. SETUP TARE MENU Programs the automatic TARE Clear function (Auto Clear), and the various Tare Modes including a means to disable Tare.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE UNITS Allows easy weight units conversions. Up to 8 Units are available. See “SETUP UNITS” in the CellScale Manual for details on activating the available units. Since Units are stored with each ID Code, the menu item for changing units is found in the “Product ID Codes” Menu. See section 3. Alternately, if changing Units is a common operation, a Function key can be programmed for the task.
MEASUREMENT SYSTEMS INTERNATIONAL SECTION 4 – FUNCTION KEYS SETUP FUNCTION KEYS The 9750A has six FUNCTION keys that can be programmed to any of several functions. The default functions are: TOTAL, CHANNEL, SEND/PRINT, ADDRESS, VIEW TOTAL, and ID. These default functions are printed on the front panel. Each key can be programmed for other functions. For example, the TOTAL key can be changed into a UNITS key. Also any of the six keys can be disabled.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE DEFAULT FUNCTION KEYS § Default Enter Functions Add to Total ....................Default for F1. Add the current weight to the total, or Auto Total On/Off. Channel ...........................Default for F2. When pressed, changes to the next channel in the Scan Index. Switch between selected scale channels. If preceded by a number (1-32), the display will show ® the chosen channel position from the Channel scan list.
MEASUREMENT SYSTEMS INTERNATIONAL it’s Host3 print string. Send to CS Host 4 ........Tells the CellScale to output it’s Host1 print string. Print & Send Host 4 .....Outputs Comm 1 print string to the DE-9 connector, and tells the CellScale to output it’s Host4 print string. Send to CS Host 5 ........Tells the CellScale to output it’s Host5 print string. Print & Send Host5 ......Outputs Comm 1 print string to the DE-9 connector, and tells the CellScale to output it’s Host5 print string.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE Quick View of Function Keys The 9750A provides a quick way to view the assigned function keys. 1) From any Weight Display press ENTER twice. The current assigned function are displayed 2) Wait 10 seconds or press ESC to return to the weight display.
MEASUREMENT SYSTEMS INTERNATIONAL SECTION 5 – ID CODES • The CellScale can store 32 ID codes. The 9750A controls which ID Code is in use. • ID Codes are created when a new name is entered by the user. The name can be all numbers, all letters, or a combination of numerals and letters. Once the name is entered by the user, the CellScale scans its memory to see if the ID Code already exists.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE SETUP ID CODES MENU Allows setup of ID Codes. A new ID can be created, the 8 character ID Name can be edited, two 20 character print strings can be assigned to each ID Code. Also any or all IDs can be deleted from this menu.
MEASUREMENT SYSTEMS INTERNATIONAL USING ID CODES To Create a New ID Code (Short method) This procedure assumes the default for ENTER F6 has not been modified by the user. 1) Press ENTER, then ID [F6]. 2) Using the numeric keypad enter a name for the new ID Code. Use the ALPHA key to select letters as required. To Create a New ID Code (Using the Setup ID menu) 1) Press SETUP, then ID [F6] or SETUP, “MORE” [7], then “Product ID Codes” [5]. 2) Select “New Product ID” [1].
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE The following procedure deletes all existing ID Codes and any totals and statistics stored in them. To Delete all ID Codes ® This procedure will delete all the product ID codes and all associated Names, Strings, Totals and Statistics for the current active channel. To delete all product IDs for all channels, you must select a channel using the CHANNEL key, then repeat this procedure for each Channel. 1) Press SETUP, then ID [F6].
MEASUREMENT SYSTEMS INTERNATIONAL SECTION 6 – TOTAL / STATISTICS TOTAL • • • • The 9750A can add independent weighments together and keep a counter of how many weighments were added (Totaled). The Weighments counter can be thought of as a box or palette counter. “TOTAL” always uses the displayed weight, so gross and net readings can be added into the same total. There are two modes of Totaling which are set in the SETUP TOTAL section.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE Auto Total Operation 1) Enable the desired Auto Total mode in the “SETUP TOTAL” menu (see “SETUP TOTAL”). Select the “AUTONORM”, “AUTOLOAD”, or the “AUTOPEAK” mode. Exit from the setup menu. 2) Use the TOTAL key to disable (“TTL OFF”) or enable (“TTL ON”) Auto Total. ® 3) Place the weight to be totaled on the scale. 4) Remove the weight. The screen will read “TOTALING” briefly, then return to the weight display.
MEASUREMENT SYSTEMS INTERNATIONAL To Set the Total Mode The following example assumes the F1 function key is in its default mode of “TOTAL”. 1) Press SETUP. 2) Press the TOTAL switch [F1] or select [6] Total. 3) The current Total Mode is shown on selection 1. 4) Press the [1] key to bring up the “Total Mode Selection” menu. 5) Select the desired Total Mode with the numeric keys (1-7). You are returned to the “Total Status” with the new mode indicated on selection 1.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE To Clear the Total Value (Current ID Code only) At any time during the following procedure the EXIT key cancels the Clear operation. Clears ID’s statistics registers as well. 1) Press VIEW ∑. The current total is displayed. 2) Press CLR. The “ARE YOU SURE” screen gives an opportunity to change your mind. ® 3) To complete the totaled weight deletion, press the ENTER key. To Clear All the Totals and Statistics of all ID Codes at once.
MEASUREMENT SYSTEMS INTERNATIONAL View Statistics and Grand Statistics The View Statistics feature uses totaled data from the current ID code in the CellScale to compute statistics. Grand Statistics uses totaled data from all ID codes. Only weight that has been totaled will be used in computing statistics. This procedure requires that F5 is programmed as “VIEW TOTAL”. 1) Press [F5].
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE SECTION 7 – 9750A SETUP SYSTEM SETUP MENU SETUP ESC ! SETUP SETUP SELECT SELECT MENU MENU 1 Function Keys 2 Set Points 3 System 4 Password Locks 5 Display Preview 6 Total 7 MORE 1/2 GHI 3 SYSTEM SYSTEM SETTINGS SETTINGS CS SW Version: 2-24 1 Key Volume is 1 2 Alarm Volume is 9 3 Backlight on 2min 4 Date & Time 5 Auto Shutdown 2hr 6 Monitor Batteries 1 KEYPRESS VOLUME VOLUME = = 1 1 KEYPRESS 1 z 2 n 3 nz 4 nn 8 nnnn 5 nnz 9 nnnnz 6 nnn 0 nnnnn 7 nnn
MEASUREMENT SYSTEMS INTERNATIONAL [3] Date Mode – Pressing [3] changes the date mode from MM/DD/YY to DD-MM-YY. [4] Time Mode – Press [4] to change between 24 hour time or 12 hour time with AM/PM indication. [5] Daylite (sic) Saving – Press [5] to select the Daylight Saving mode. Select “ON” when in Daylight Savings Time (adds 1 hour). Select “OFF” when not in Daylight Savings time. Select “AUTO” to allow the 9750A to automatically enter into and out of daylight savings time (follows US rules).
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE RESET ALL: The following procedure will cause you to lose all setups and will return the 9750A to it’s default settings. Use this procedure only as the last resort of having lost your password. ® 1) Press POWER followed immediately by ESC (SETUP). The startup screen will appear. 2) Press the CLR (ZERO) key. A password text entry screen will appear. 3) Using the keypad, input the number 7415369. Press ENTER. 4) The “ARE YOU SURE” display appears.
MEASUREMENT SYSTEMS INTERNATIONAL xS or xSL............ The Scan List Index position as stored in the CellScale where x is 1-8. Used on multiple display presets to show which scan list position is included on the preset display. These can be later altered to any scan list position 1-32. SLI ...................... Scan List Index position displayed in the form xSL (positions 1-9) or xxS (positions 10-32). x’s-Weight .......... Current weight from scan list position x. x’s-Ch-Name ......
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE Multi-Channel Preset Displays Multi-channel presets use the scan list position to assign channels to specific locations. After selecting the preset multi-channel display, the user can reassign any channel in the scan list to any screen location. The Multi-Channel Preset Displays are described by line numbers 1-8 ® corresponding to the small font layout. The numbers in the sample screens and descriptions correspond to the scan list position index (SLI).
MEASUREMENT SYSTEMS INTERNATIONAL SCALE DISPLAY SETUP MENU – PRESET DISPLAYS SETUP ESC ! Shortcut DISPLAY EXIT SCALE DISPLAY SETUP 1 Single Scale Mode 2 Multi Scale Mode 3 Backlight 2min 4 Backlight Level 3 5 Contrast 16 6 Tp Compensation 0 6 Tp Comp START 35°C BACKLIGHT 1 Off (max batt-life) 2 On for 15 seconds 3 On for 30 seconds 4 On for 1 minute 5 On for 2 minutes 6 On (min batt-life) 7 Light on Motion OFF 7 Light on Motion ON 7 Light on Motion OFF MULTI CH 0 Number 1 3 Ch 2 2 Ch 3 4 Ch 4 4 Ch
9750A HANDHELD RF REMOTE INDICATOR for 2 CELLSCALE Multi Scale Mode – Accesses multi channel display presets and multi channel custom menus. The various display modes are described on the previous page. Backlight – Controls the duration of the backlight. The duration resets every time a key is pressed. Setting for shorter times increases battery life. 3 USING DISPLAY SETUP ® The 9750A weight display is a primary means of getting and using CellScale data.
MEASUREMENT SYSTEMS INTERNATIONAL CUSTOM DISPLAY SETUP The 9750A weight display is fully customizable. Both the single channel and multi-channel displays can be customized. All available data types plus custom text can be located anywhere on the screen in any of three font sizes: 1) Large Font – Used primarily for weight displays, the large font offers up to 8 characters in two rows.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE Screen Formatting Rows 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Rows Rows The 9750A LCD Screen allows a wide variety of scale display screen setups. The illustrations here demonstrate some of the possibilities. The custom display setup menus control the type and placement of available data types. The LCD is a graphics type organized in rows and columns. The row size is fixed at 8 rows of 8 pixels each for a ® total vertical size of 64 pixels.
MEASUREMENT SYSTEMS INTERNATIONAL Line Preview The bottom two lines of the Row Setup menu illustrate what the line has programmed into it. Data is displayed in row pairs. For example, while programming row 6, row 5 and 6 will be illustrated. When data from another line is present, as it will be with the large font, the preview area will show as lines.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE Selecting Items for Display The custom display setup menus provide access to all the data the scale can provide. When an item is present on the display, it will have an arrow next to its selection number. The length of some data items are fixed, but many have variable lengths. When an item is selected for the first time, a number entry screen will appear (if it is a ® variable length data item) allowing you to decide the length of the data.
MEASUREMENT SYSTEMS INTERNATIONAL CUSTOM SINGLE CHANNEL DISPLAY SETUP MENU SETUP ESC ! Shortcut STU 7 DISPLAY EXIT DEF 2 ROW ROW X-X X-X XX XX CHARACTERS CHARACTERS 1 Product ID 2 Net-Gross-Tare Wt 3 Channel Info 4 Miscellaneous 5 Date-Time Preview Line Area SCALE DISPLAY DISPLAY SETUP SETUP SCALE 1 2 3 4 5 Single Scale Mode Multi Scale Mode Backlight 2min Backlight Level 3 Contrast 1Ø ABC 1 ABC SINGLE SINGLE SCALE SCALE CHANNEL CHANNEL DISPLAY MODE MODE DISPLAY 1 Standard Weight 2 Net Gros
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE CUSTOM MULTI-CHANNEL DISPLAY SETUP MENU SETUP ESC ! Shortcut STU 7 DISPLAY EXIT DEF DEF PQR 2 2 6 SCALE DISPLAY SCALE DISPLAY SETUP SETUP 1 2 3 4 5 Single Scale Mode Multi Scale Mode Backlight 2min Backlight level 3 Contrast 10 MULTI MULTI CH CH 0 Number 1 3 Ch 2 2 Ch 3 4 Ch 4 4 Ch 5 8 Ch 6 Custom ROW ROW X-X X-X XX XX CHARACTER CHARACTER 1 Product ID 2 Net-Gross-Tare Wt 3 Channel Info 4 Miscellaneous 5 Date-Time Preview Line Area ® DISP DI
MEASUREMENT SYSTEMS INTERNATIONAL SECTION 8 – SET POINTS INTRODUCTION The CellScale system provides extensive Set Point capabilities. Up to 32 Set Points are available. The CellScale performs the A/D conversions and does limit checking for all the Set Points. The 9750A receives Set Point information from the CellScale and responds as programmed. All 32 Set Points are setup from either the CellScale Terminal Interface, from a 3750CS, or from the 9750A.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE SET POINT SETUP MENU There are three ways to program values, operators, and remote relays for Set Points. 1) Use the Terminal Interface Mode at the CellScale, 2) use a 3750CS, or 3) use the 9750A. To Enter the Set Point Setup Menus ® 1) Press SETUP. 2) Select “Set Points” by pressing [2]. 3) The “MASTER SET POINTS” menu appears. Menu items 1-5 are discussed next.
MEASUREMENT SYSTEMS INTERNATIONAL PROGRAM SET POINT MENU 1 2 3 4 5 6 7 8 SP XX -SPName- OFF 9750 Response OFF Input Source XX Output Assign XX Delay XXXXXms Latch OFF Force On OFF Formula 9 View T edit Set Point To Name ALPHA a A 1 1 ABC This Set Point Menu is reached from the procedure on the previous page. 1) Individual Set Points are turned on (enabled) or off (disabled) by pressing [1]. Disabled Set Points can still be programmed, but will not operate until enabled.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE 9750A RESPONSE MENU The 9750A responds to set points in three ways: with an audible alarm, a message display, or a message sent to comm port 1. These menus program this response. ® SET POINT XX XX SET POINT 1 Audible Alarms 2 Alarm Display 3 Alarm to Comm2 OFF OFF OFF 1) Audible Alarms – 5 different tones are available for the tripped condition and/or the reset condition.
MEASUREMENT SYSTEMS SET POINT FORMULA MENU INTERNATIONAL FORMULA SP XX XX FORMULA SP 1 Operator 1 > 2 Value 1 XXXXXXX 3 Val 1 Type GROSS 4 Dual Value OFF 5 Preact XXXXXXX 6 Deadzone XXXXXXX 7 View Formula The Set Point Formula Menu controls the compare values and Set Point type selection. OPERATOR 1 OPERATOR 1 ABC DEF 1) Operator 1 – Use the sub-menu to select the compare operator. In dual value alarms, this operator only applies to value 1.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE SECTION 9 – COMMUNICATION PORTS INTRODUCTION • • • The MSI 9750A is equipped with a single RS-232 serial input /®output. The Comm Port is intended for interfacing printers, data loggers, scoreboards, and computers to the 9750A Meter. The real-time clock allows the user to time and/or date stamp any data obtained from the 9750A. Planned for future release is an interface to Bar Code Scanners. The data output is fully format able.
MEASUREMENT SYSTEMS INTERNATIONAL the weight is in motion and/or not stable. 3) Print on CTS (Clear to Send, a RS-232 handshake line) – By toggling the CTS line from space to mark, the print string will be transmitted. If an interval is set, the string will continue to print as long as CTS is asserted. “Motion Check” determines if printing is allowed (Motion Check Off) or disallowed (Motion Check On) when the weight is not stable.
9750A SETUP ESC ! HANDHELD RF REMOTE INDICATOR for SETUP SETUP SELECT SELECT MENU MENU 1 Function Keys 2 Set Points 3 System 4 Password Locks 5 Display Preview 6 Total 7 MORE 1/2 [3] TRIGGER PRINT ON: The “Trigger Print On’ menu designates the condition that causes the 9750A to output data. The Send / Print key will always work unless specifically locked out or the function key is reassigned.
MEASUREMENT SYSTEMS INTERNATIONAL 5) MODE: The MODE menu sets the communications mode for the port. Use “TALK” for outputting data to a printer that uses hardware handshaking or no handshaking. Use “DUPLEX” for printers with software handshaking (XON / XOFF, etc.) or to talk and listen to a computer. Use “LISTEN” to only receive commands from a computer. Use “OFF” to disable the port (and save power on battery units). [5] MOTION CHECK: When ON the scale will only print settled data, i.e.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE GENERAL TEXT ENTRY MENU ADDRESS F4 Len 0 F4 Menu Max 512 ENT Save Pos 1 -NAMEofSTRING- 1 ASCII CHARACTERS CHARACTERS ASCII 1 Punctuation 2 Printable Symbols 3 Control Characters 4 Enter Decimal Char 5 Full Screen OFF 6 Size SMALL 20/ROW Show 79 Characters PUNCTUATION PUNCTUATION MENU MENU ® 1 , 2 ; 3 : 4 .
MEASUREMENT SYSTEMS INTERNATIONAL Alternate Characters, Punctuation, Symbols, and Control Characters 1) While in the text entry screen, press the [F4] key. This enables the ASCII Characters Menu. This menu provides links to special characters. 2) For standard punctuation, press [1]. For other printable characters, press [2]. For ASCII control characters, press [3]. If a special character is needed, use the “Enter Decimal Char” [4] menu to put in the decimal equivalent value of the desired character.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE 6) @W3 causes the current Net weight to be printed. If the scale was in the NET mode, @W1 would have worked as well. 7) @D6 causes the current date to be printed in MM/DD/YYYY format 8) @E causes the end-of-line string to be sent (CR/LF). ® PROGRAMMING THE END OF LINE OR START OF LINE STRINGS The End of Line String is used to terminate print strings and is printer dependent. The default string is Carriage Return (CR=ASCII 13d), Line Feed (LF=ASCII 10).
MEASUREMENT SYSTEMS INTERNATIONAL SERIAL OUTPUT “@” COMMANDS The printer formatting “@” commands and their data configurations are as follows: Description Cmd Command Suffix Input examples Reset the host parser ; None Select Active Channel @nn where “nn” is the channel list location 01-32 @05 Change to next channel w/ Labels @+ None @+ @- None @- 1=Current Scan Index 2=Current Display Index @? Change to previous channel w/ Labels Query for current scan list posi- @? tion ; @26 Outpu
9750A HANDHELD RF REMOTE INDICATOR for Description Print Modem ID Cmd @I Command Suffix 1 CELLSCALE Input examples @I1 Output examples & comments *= a space or place holder xxx where x is the modem ID from 1-254 ® Output ID String @L Output a scale mode @M Output Name @N Output Comm Port Data String @P 1=ID String 1 2=ID String 2 1=Current 2=Gross 3=Net 4=Tare 5=Total 6=# Totals 7=Total, #Ttls 8=reserved 9=Last Total % 1=Current Channel Name 2=Current ID Name 3=Current Set Point 4=Scan List P
MEASUREMENT Description SYSTEMS Cmd Output Weight Value and mode @W INTERNATIONAL Command Suffix 1=current weight Input examples @W1 **20.002*LB***GROSS* 2=gross @W2 **205.08*KG***GROSS* 3=net @W3 4=tare @W4 5=total @W5 6=# of totals @W6 7= total, # of totals @W7 8=reserved Output a statistics value Output examples & comments *= a space or place holder 9=last totaled weight @W9 %= Per Cent of Capacity @W% Length: 20, fixed. Leading zeros suppressed Length: 20, fixed.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE SECTION 10 – DATA LOGGING INTRODUCTION The 9750A has two battery backed memory locations for storing scale data. Predefined function keys are available for storing user configured data directly to either memory location. Data Logging uses the “Data Out String” and “Aux String” to store user defined data at the press of a button. Usually the “Data Out String” is programmed with the weight configured as desired.
MEASUREMENT SYSTEMS INTERNATIONAL DATA LOGGING CONTROL MENU The Data Logging Control Menu provides a means to upload stored data, and erase the data logging memory locations. The Data Logging Control Menu is reached by pressing SETUP followed by NET/GROSS. Alternately the menu can be reached through the Comm Port and Strings Menu.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE SECTION 11 – TEXT MESSAGING The MSI-9750A provides a means for sending messages from host computers directly to the 9750A display. The remote computer uses a host command to send data to any 9750A on the same network (0-31). Once the 9750A receives a text message, it is displayed until a key is pressed. By®including the standard ASCII bell character (control G), the message can also send an alert tone that persists until the message is acknowledged.
MEASUREMENT SYSTEMS INTERNATIONAL 9750A TO HOST MESSAGES Once a sent message is observed by the 9750A user, pushing any key will clear the message and return the 9750A to the last display mode. An acknowledgment string is automatically sent back to the modem that generated the message. The acknowledgment string is programmed in the Comm Port Setup menu. The string defaults to the ASCII “ACK” character but can be modified in the “Enter/Edit Strings” choice of the Comm Port Setup menu.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE Th is Pa ge In te nt io na lly Le ft Bl a nk ® Page 68 MSI-9750A RF Remote Indicator • User Guide
MEASUREMENT SYSTEMS INTERNATIONAL SECTION 12 – BAR CODE The Bar Code features of the 9750A allow the user to add scanned data to weight readings and trigger transmissions directly into RF connected computers. In combination with the Data Logging features, bar code scans can trigger data storage for uploading later. Bar Code data is directed into text fields under user control. Four strings, K1 (Bar Code 1), K2 (Bar Code 2), K3 (Bar Code 3), and K4 (Bar Code 4) are sized to accept up to 64 bytes.
9750A CELLSCALE HANDHELD RF REMOTE INDICATOR for SETUP ESC ! SETUP SELECT SELECT MENU MENU SETUP 1 Function Keys 2 Set Points 3 System 4 Password Locks 5 Bar Code 6 Total 7 MORE 1/2 To set up the Bar Code reader, press SETUP then [5]. 1) BarCode 1 – The sub-menu designates the output mode when data comes in for Bar Code 1. [1] Selecting 1 will send the data to the master CellScale’s Comm Port 1.
MEASUREMENT SYSTEMS INTERNATIONAL SECTION 13 – CHANNEL SETUP & CALIBRATION CHANNEL SETUP MENU SETUP ESC ! Shortcut STU 7 CHANNEL F2 ABC 1 CHANNEL / CALIBRATION --Channel Name---Chn---Index-1 Channel is ACTIVE 2 Filter LOW 3 Calibrate Settings 4 Start Calibration 5 Zero RUSure Msg ON ABC F2 Changes to the next Channel available The Channel Setup Menu provides control of Channel settings in the CellScale.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE CALIBRATE GENERAL INFORMATION The following sections are intended for qualified scale technicians. The CellScale can be calibrated either directly using the Terminal Interface mode, or by using a 9750A or 3750CS. See the CellScale operators guide for informa® tion on direct calibration. This section details the calibration of a CellScale using the 9750A RF Remote Indicator.
SETUP ESC ! SYSTEMS Shortcut STU 7 CHANNEL F2 ABC 1 INTERNATIONAL CHANNEL / / CALIBRATION CALIBRATION CHANNEL --Channel Name---Chn---Index-1 Channel is ACTIVE 2 Filter LOW 3 Calibrate Settings 4 Start Calibration 5 Zero RUSure Msg ON CHANNEL F2 Changes to the next Channel available JKL If Disabled (Sealed) MEASUREMENT 4 CalibrationDisabled 4 ENTER to Recalibrate CLR to Reset Cal ESC to Exit Cal ZERO ENTER CLR 0 RESETING CALIBRATION CALIBRATION CALIBRATION UNITS UNITS 1 Pounds 2 Kilogram
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE TO ENABLE / DISABLE AZM (AUTO ZERO MAINTENANCE) AZM is used to adjust out variations at zero caused by debris or water on the scale, temperature drift, and any other minor variation that affects the zero setting. Typically AZM is set to 0.5d or 1d, which is adequate for most ® modern scale systems. The CellScale allows for a much greater AZM range (non legal-for-trade scales only) for unique applications.
MEASUREMENT SYSTEMS INTERNATIONAL CENTER-OF-ZERO (COZ) INDICATOR The COZ indicator turns on when the scale is within 1/4 d of the last zero setting. Some legal-for-trade jurisdictions require its use. To Enable/Disable the COZ Indicator Before starting the following procedure, you must be in the Top Menu Level of Calibration. 1) 2) 3) 4) Press SETUP, then CHANNEL. Select “Calibration Settings” [3]. Toggle the Center of Zero indicator on or off with the [4] key.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE INSTALLING FIRMWARE UPDATES The 9750A contains Flash memory that allows the firmware to be upgraded through the Comm Port. A “Boot Loader” program is used to load a new program file into the 95750. MSI will update and improve the 9750A feature set over time and provide program updates free of charge. ®Please see MSI’s web page (www.msiscales. com) to download the most current 9750A firmware.
MEASUREMENT SYSTEMS INTERNATIONAL _+)#!!!_+)#!!!_+)#!!!_+)#!!!_+)#!!!_+)#!!!_+)#!!!_+)#!!!_ #!!!_+)#!!!_+)#!!!_+)#!!!_+)#!!!_+)#!!!_+)#!!!_+)#!!!_+)# before matching baud rates When you can read this, press any key. after matching baud rates When you can read this, press any key. When you can read this, press any key. MSI Boot Loader Version 3.K3 (1) (2) (ESC) Update Application Change Baud Rate Start Application Enter Command : 10) Choosing “Update Application” will request that the file be uploaded.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE MSI Boot Loader Version 3.K3 (1) (2) (ESC) Update Application Change Baud Rate Start Application ® 12) After all sectors are programmed, press the POWER key on the 9750A. The 9750A will turn off. Remove the serial cable from the 9750A Comm Port. 13) Turn the 9750A back on. The 9750A display will read “CLEARING” while it initializes all setup registers. 14) Restore display and other system parameters as needed.
MEASUREMENT SYSTEMS INTERNATIONAL APPENDIX A – MENU MAPS SETUP SELECT MENU SETUP ESC ! SETUP SETUP SELECT SELECT MENU MENU 1 Function Keys 2 Set Points 3 System 4 Password Locks 5 Display Preview 6 Total 7 MORE 1/2 STU 7 SETUP SETUP SELECT SELECT MENU MENU 1 Channel & Calibrate 2 Display 3 RF Modem 4 Comm 2 & Strings 5 Product ID Codes 6 Tare 7 MORE 2/2 STU 7 PASSWORD LOCKS SETUP ESC ! SETUP SELECT SELECT MENU MENU SETUP 1 Function Keys 2 Set Points 3 System 4 Password Locks 5 BarCode 6 Total
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE FUNCTION KEYS SETUP ESC ! SETUP SELECT MENU 1 Function Keys 2 Set Points 3 System 4 Password Locks 5 Display Preview 6 Total 7 MORE 1/2 FUNCTION KEY ASSIGNS 1 F1 is Add to Total 2 F2 is Next Channel 3 F3 is Send to CS 4 F4 is Next Address 5 F5 is View Total 6 F6 is Next Prod ID 7 Enter-FKey Assigns Any Number Key 1-6 F4 shown for example ENTER-FKEY ASSIGNS 1 E1 is Clr Last ∑ 2 E2 is Back Channel 3 E3 is Print Comm 1 4 E4 is Back Address 5 E5 is View G
MEASUREMENT SYSTEMS INTERNATIONAL SERIAL & STRINGS SETUP ESC ! SETUP SETUP SELECT SELECT MENU MENU 1 Function Keys 2 Set Points 3 System 4 Password Locks 5 Display Preview 6 Total 7 MORE 1/2 SEND/PRINT IN Shortcut SETUP SELECT SELECT MENU MENU SETUP 1 Channel & Calibrate 2 Display 3 RF Modem 4 Comm 2 & Strings 5 Product ID Codes 6 Tare 7 MORE 2/2 COMM 1 1 STRINGS STRINGS COMM 1 Data Out String 2 End of Line 3 Start of Line 4 Wait Character 5 Aux String 6 Ack String 7 Overload String 6 Firmware
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE PRODUCT ID CODES SETUP ESC ! SETUP SELECT SELECT MENU MENU SETUP 1 Function Keys 2 Set Points 3 System 4 Password Locks 5 BarCode 6 Total 7 MORE 1/2 SETUP SELECT SELECT MENU MENU SETUP 1 Channel & Calibrate ® 2 Scale Display Line 3 RF Modem 4 Comm 2 & Strings 5 Product ID Codes 6 Tare 7 MORE 2/2 ID SETUP Shortcut PRODUCT ID ID Chan X-X X-X PRODUCT Chan Net XX ID IDName-1 New Product ID 2 ID Units kg 3 Edit ID Strings 4 Edit ID Name 5 Display Mode NO
MEASUREMENT SYSTEMS TARE SETTINGS SETUP T TARE Shortcut ESC ! STU T PQR 7 6 INTERNATIONAL TARE TARE SETTINGS SETTINGS -CHANNEL NAME or NUM1 2 3 4 5 Disable Auto Clear Set Clear on Minus Set Clear on Total Tare by Product ID Same Tare All ID’s RF MODEM SETTINGS SETUP ESC ! Shortcut STU 7 ADDRESS F4 GHI ABC 3 1 MODEM SETTINGS SETTINGS v2.05 v2.
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE SCALE DISPLAY SETUP SETUP ESC ! Shortcut DISPLAY EXIT SCALE DISPLAY SETUP 1 Single Scale Mode 2 Multi Scale Mode 3 Backlight 2min 4 Backlight Level 3 5 Contrast 16 6 Tp Compensation 0 6 Tp Comp START 35°C ® BACKLIGHT 1 Off (max batt-life) 2 On for 15 seconds 3 On for 30 seconds 4 On for 1 minute 5 On for 2 minutes 6 On (min batt-life) 7 Light on Motion OFF 7 Light on Motion ON 7 Light on Motion OFF MULTI CH 0 Number 1 3 Ch 2 2 Ch 3 4 Ch 4 4 Ch 5 8
MEASUREMENT SYSTEMS INTERNATIONAL SCALE SINGLE CHANNEL CUSTOM DISPLAY SETUP SETUP ESC ! Shortcut STU 7 DISPLAY EXIT DEF 2 ROW ROW X-X X-X XX XX CHARACTERS CHARACTERS 1 Product ID 2 Net-Gross-Tare Wt 3 Channel Info 4 Miscellaneous 5 Date-Time Preview Line Area SCALE DISPLAY DISPLAY SETUP SETUP SCALE 1 2 3 4 5 Single Scale Mode Multi Scale Mode Backlight 2min Backlight Level 3 Contrast 1Ø ABC 1 ABC SINGLE SINGLE SCALE SCALE CHANNEL CHANNEL DISPLAY MODE MODE DISPLAY 1 Standard Weight 2 Net Gros
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE SCALE MULTI-CHANNEL CUSTOM DISPLAY SETUP SETUP ESC ! Shortcut STU 7 DISPLAY EXIT DEF DEF PQR 2 2 6 SCALE DISPLAY SCALE DISPLAY SETUP SETUP 1 2 3 4 5 Single Scale Mode Multi Scale Mode Backlight 2min Backlight level 3 Contrast 10 MULTI MULTI CH CH 0 Number 1 3 Ch 2 2 Ch 3 4 Ch 4 4 Ch 5 8 Ch 6 Custom ROW ROW X-X X-X XX XX CHARACTER CHARACTER 1 Product ID 2 Net-Gross-Tare Wt 3 Channel Info 4 Miscellaneous 5 Date-Time Preview Line Area ® DISP D
MEASUREMENT SYSTEMS CHANNEL / CALIBRATE SETTINGS SETUP ESC ! Shortcut STU 7 CHANNEL F2 ABC 1 INTERNATIONAL CHANNEL / CALIBRATION --Channel Name---Chn---Index-1 Channel is ACTIVE 2 Filter LOW 3 Calibrate Settings 4 Start Calibration 5 Zero RUSure Msg ON ABC F2 1 Channel is 1 Channel ACTIVE INACTIVE CHANNEL FILTER CHANNEL FILTER DEF CHANNEL 1 Changes to the next Channel available 2 1 Low 2 Medium 3 High CALIBRATE CALIBRATE SETTINGS SETTINGS GHI JKL MNO ABC 3 4 1 2 3 4 5 -CHN1-1 M
9750A HANDHELD RF REMOTE INDICATOR for SYSTEM SETTINGS SETUP ESC ! SETUP SETUP SELECT SELECT MENU MENU 1 Function Keys 2 Set Points 3 System 4 Password Locks 5 Display Preview 6 Total 7 MORE 1/2 GHI 3 SYSTEM SYSTEM SETTINGS SETTINGS CS SW Version: 2-24 1 Key Volume is 1 2 Alarm Volume is 9 3 Backlight on 2min 4 Date & Time 5 Auto Shutdown 2hr 6 Monitor Batteries CELLSCALE GHI POWER SETUP T TARE ESC T ! 2 ALARM VOLUME VOLUME = = 8 ALARM 8 1 z 2 n 3 nz 4 nn 8 nnnn 5 nnz 9 nnnnz 6 nnn 0 nnnnn
SYSTEMS CALIBRATION SETUP ESC ! Shortcut STU 7 CHANNEL F2 ABC 1 INTERNATIONAL CHANNEL / / CALIBRATION CALIBRATION CHANNEL --Channel Name---Chn---Index-1 Channel is ACTIVE 2 Filter LOW 3 Calibrate Settings 4 Start Calibration 5 Zero RUSure Msg ON Changes to the next Channel available CHANNEL F2 4 CalibrationDisabled CALIBRATION LOCK PRESS SEALSWITCH ON CELLSCALE TO CONTINUE OR CALIBRATION DISABLED, CYCLE CELLSCALE POWER TO CONTINUE RESET ALL OR RESET RF MODEM If a Password is Set POWER SETUP
9750A HANDHELD RF REMOTE INDICATOR for CELLSCALE GENERAL TEXT ENTRY ADDRESS F4 Len 0 F4 Menu Max 512 ENT Save Pos 1 -NAMEofSTRING- 1 ASCII CHARACTERS CHARACTERS ASCII 1 Punctuation 2 Printable Symbols 3 Control Characters 4 Enter Decimal Char 5 Full Screen OFF 6 Size SMALL 20/ROW Show 79 Characters PUNCTUATION PUNCTUATION MENU MENU ® 1 , 2 ; 3 : 4 .
MEASUREMENT SYSTEMS INTERNATIONAL SET POINTS MASTER MASTER SET SET POINTS POINTS SETUP ESC DEF ! DEF GHI JKL 2 2 3 4 1 2 3 4 5 6 ABC Program Set Point Set Points ENABLED View Status View Status w/Name Clear Latches Mom Timeout Ø.
9750A HANDHELD RF REMOTE INDICATOR for APPENDIX B – ASCII CHART ® Page 92 MSI-9750A RF Remote Indicator • User Guide CELLSCALE
MEASUREMENT SYSTEMS INTERNATIONAL APPENDIX C – SPECIFICATIONS & SUMMARY OF FEATURES Temperature Range • -20° C to +60° C Operating (-4° F to 140° F) • -30° C to +80° C Storage (-22° F to 176° F) Approvals (planned or pending) NTEP, OIML, Factory Mutual, FCC Radio Link Frequency Hopping Spread Spectrum in 64 networks@ 2.4 GHz. Radio functions in the ISM band, license free in the USA and Europe. 10mW (low power) or 100mW (high power) average output.
THE MSI LIMITED WARRANTY MEASUREMENT SYSTEMS INTERNATIONAL, INC., WARRANTS load sensing elements and meters against defects in workmanship and materials for a period of one year from date of purchase and warrants electrical cables and batteries against the same defects for a period of ninety (90) days from date of purchase. Any device which proves defective during the warranty period will be replaced or repaired at no charge; provided that the defective device is returned to the Company freight pre-paid.
Measurement Systems International TM A RICE LAKE WEIGHING SYSTEMS COMPANY 14240 Interurban Avenue South Suite 200 Ɣ Seattle, WA 98168-4661 Ɣ USA Phone: 206-433-0199 Ɣ Fax: 206-244-8470 www.msiscales.