User guide

17DXC910 OPERATIONS MANUAL 2007/05/17
Example: Change the call numbers from default 100-155 to 200-255. This is useful when two or more
exchanges are connected via Tie-line. Use the R(range) option to assign call numbers to a range of line
equipment numbers.
>SCN
cr
Call Number <100-999/*> : 200-255
cr
Line Equipment Number (R=range, S=single) <R/S> : R
cr
Line Equipment Number <$00..$3F> : 00
cr
>LLE
cr
Line Equipment Number <$00-$37/*> : 00-03
cr
Line Call In Priority
Equ. Number Caller ID Type QUE Alarm Call Annunciator Printer Video
==== ========= ========== ==== ==== ===== ==== =========== ======= =====
$00 200 ICM RING 1 3 ... ... ...
$01 201 ICM RING 1 5 ... ... ...
$02 202 ICM RING 1 5 ... ... ...
$03 203 ICM RING 1 5 ... ... ...
>
Example: Connect a Tie-line unit from the other exchange (100-155) to Line Equipment 00.
Use the S(single) option to assign call numbers to a single line equipment number (the Tie-line).
>SCN
cr
Call Number <100-999/*> : 100-155
cr
Line Equipment Number (R=range, S=single) <R/S> : S
cr
Line Equipment Number <$00..$3F> : 00
cr
>LLE
cr
Line Equipment Number <$00-$37/*> : 00-03
cr
Line Call In Priority
Equ. Number Caller ID Type QUE Alarm Call Annunciator Printer Video
==== ========= ========== ==== ==== ===== ==== =========== ======= =====
$00 100--155 ICM RING 1 3 ... ... ...
$01 201 ICM RING 1 5 ... ... ...
$02 202 ICM RING 1 5 ... ... ...
$03 203 ICM RING 1 5 ... ... ...
>
When calls are made to call numbers between 100 and 155 the Tie-line will send the calls to the other
exchange.