Service manual

35
Maintenance
DRAWING D
Filter , Flow / By Pass Servo`s and Flow Sensor
1. To remove Flow (A) and Bypass (B) servo`s undo screws (2) and remove clips pull forward the
two pipes
2. Undo the 4 screws (1) situated outside of the case on the base then lift both units out and dis-
connect the units individual plug and sockets (see drawing G connections 5 & 5A)
3. To separate both units undo screws (3) and pull apart
4. To remove flow sensor (D) undo screw (3) and un plug its connection (see drawing G connec-
tion 5C)
5. To replace anti frost heater (C) remove flow sensor (D)
6. Reverse to re-build ENSURE `O` Ring `E` IS IN PLACE
7. Filter (F) is removed by unscrewing from the appliance fitting
DRAWING E