Corp. Indoor Fireplace User Manual

Rinnai Corporation RHFE-750ETRA 25
6. Unscrew the flue access panel held by two
screws located inside the top left hand corner of
the appliance. Slide this panel to the right behind
the convection fan.
Connections
1. Carefully remove the packaged ceramic logs and
place in a safe location.
2. To ensure the correct positioning, terminate the
gas supply so that it is 5.9 inches (150 mm) from
the front of the enclosure.
3. Gain access to the gas connection by removing
the right hand side access panel and by
unscrewing the four retaining screws. Pry the
front edge of the panel open to the right and pull
forwards.
4. Position the appliance in front of the enclosure so
that the end of the gas supply aligns with the gas
fitting opening. Connect the flexible gas
connection to the gas supply.
5. Replace the right hand panel and secure with the
four retaining screws.
7. Remove the 2 screws attaching the cover on the
junction box. Install the power cord flex clamp by
inserting the threaded part through the bottom
hole and attaching the washer. Attach the
electrical connection and place in the junction
box. Attach the cover with 2 screws.
8. Leak test the gas connection using a soapy
solution. Do not allow the soapy solution to
contact electrical components. Remove any
residue.
gas fitting opening gas connection
remove 4
screws to
remove
side
panel