User Guide

Operating instructions Rinnai E-Series
13
Holiday period:
Adjust the thermostat* to the holiday period. See
the user thermostat manual. The hot water facility
can be switched off by means of the program
button on the control panel.
Re-setting the central heating system:
Switch off the three program buttons , ,
when these are activated. Switch off the power
supply. When the boiler is being drained one
should take into account that a part of the heating
water will remain in the boiler. When risk of freezing
arises one should take care that the remaining
central heating water in the boiler does not freeze.
Holiday
* If you have a RS100
thermostat it is provided
with a holiday program.
The holiday period can be
adjusted on the thermostat
itself. The central heating
and DHW supply are
switched off during that
period. There is also the
option that only the central
heating is switched off. With
all of these possibilities the
freeze protection system
is active.
Theboilerwillnotfunctiondirectly.Theautomaticde-aerationprogramofabout
17minuteswillstartafteroneofthethreeprogrambuttonsispressed.Thedisplay
willshow whereAstandsforAutomaticde-aerationprogramActiveand
thenumberontherightindicatestheactualwatertemperatureoftheboiler.
Check the water pressure regularly and top up the installation when
necessary.
The working pressure of the installation should be between 16 and 18 PSI
It can take a while before all air has disappeared from a lled installation.
Especiallyintherstweeknoisescanbeheardwhichindicatethepresenceof
air.Theautomaticairventintheboilerwillremovetheair,whichmeansthewater
pressurewillreduceduringthisperiodandthereforetoppingupwithwaterwill
benecessarytoadjusttheowwatertemperature
Turning the boiler off