Specification guide Continuous flow water heating
Important This guide has been written to help you select and order the right Rinnai continuous flow water heater, associated components, and accessories for the right job. This information is not intended as an installation guide. Rinnai is constantly improving its products, and as such, information and specifications are subject to change or variation without notice. For the most up-to-date information go to www.rinnai.co.nz.
: s t n e t n co Leaders in continuous flow.....................................4 What is continuous flow?.........................................5 Continuous flow summary table.............................6 Model selection - domestic applications................7 Product selector - domestic applications...............8 Rinnai Infinity digital water controllers...................9 Specifying commercial solutions............................10 Designing central water heating systems...............
Leaders in continuous flow When you turn on a tap, you want water at the right temperature fast. Which is why, over the years, we’ve devoted considerable time and resource to leading edge research and development. We were the first to introduce continuous flow technology, and have been tirelessly working on improving this ever since. Our commitment to bring you the latest in technology has resulted in the next generation of water heaters.
What is continuous flow? It is exactly that—a continuous flow hot water system. Unlike storage tanks that can run out, continuous flow units deliver a pre-determined flow rate every minute for as long as the unit is running.
Continuous flow summary table Model Mounting position Application suitability Energy Input star rating Output Thermal eff. on high Status monitor Infinity VT16 External Domestic 6.2 125 MJ/h or 35 kW 29.6 kW 81% No Infinity VT20 External Domestic 5.9 160 MJ/h or 44 kW 34.9 kW 80% No Infinity VT24 External Domestic 5.8 188 MJ/h or 52 kW 42.1 kW 80% No Infinity VT26 External Domestic 5.8 199 MJ/h or 55 kW 44.
Model selection - domestic applications When specifying residential hot water applications there are some basic questions that you need to ask in order to correctly design a system. You also need to bear in mind future requirements of the building. The key point is water heating solutions should be designed to the number of outlets and not people.
Product selector - domestic applications Your budget, size of house, number of outlets, and hot water requirements all factor in determining the right continuous flow hot water system for your home. Use the product selector below to work out which model is right for you. 1. Determine the hot water outlets that will run simultaneously in your house, and list the flow rates against them.
Rinnai Infinity digital water controllers With a Rinnai Infinity digital controller, you choose your own personalised settings. Just select the water temperature you want (37-55 °C) in up to four different locations. This means you can set water at a safe temperature in the bathroom (a great safety feature), then set it higher, if you wish, in the kitchen and laundry.
Specifying commercial solutions Rinnai Infinity HD/EF units, manifolded units ( joined together), Demand Direct, Demand Duo, and Demand Rapid can provide all the hot water for large demand applications such as sports clubs, restaurants, motels, and apartment projects. For full details on Rinnai’s Demand solutions, please refer to the Commercial Water Heating catalogue available on our website www.rinnai.co.nz/waterheating_ brochures.html.
Designing central water heating systems Performance of Rinnai continuous flow units are directly related to hours of use and how well they are maintained. It is important when designing central water heating systems that they are sized correctly. This will extend the life of the system and reduce ongoing maintenance and servicing costs. Design principles 1. The Rinnai system should be regarded as a continuous flow system with storage back-up.
Fault indication In multiple unit installations it is important to know if a water heater is faulting. If a water heater is faulting this increases the wear and tear on the water heaters and will cause progressive reduction in the hot water supply if more units fail. Rinnai HD/EF water heaters can be fitted with a Rinnai HD Error Indication Switch (part R1070), volt free contact, which will close to indicate a water heater is not operating.
Manifold electronic control system (MECS) Infinity units can be manifolded together (up to 25) by connecting them in parallel to enable a greater hot water flow rate than is possible with a single unit. MECS is a totally integrated system, unique to Rinnai, that links each Infinity unit in the system and will turn on each unit as required. The system is designed to ensure gas is not wasted and that an endless supply of hot water is always available.
Circulating ring mains with Rinnai Infinities Hot water immediately when you turn on the tap—circulating ring mains give hot water instantly at all outlets. High temperature circulating ring main Notes on circulating systems with Infinity water heaters REUMSBMB (MECS master slave kit) Cylinder volume should be > 10 x the pipe volume between the Rinnai water heater and cylinder. Temper outlets as required with point-of-use tempering valves.
Positioning continuous flow units In order to provide safe and effective water heating it is important to adhere to all relevant gas installation standards. Prior to purchasing or siting an appliance check the guidelines detailed in this section. Internal models Internal models are designed for indoor installations only. They may be installed in an enclosure if the requirements of AS/NZS 5601.1 are satisfied.
General flue clearances - external models The following diagram has been provided to assist in determining where, and if an external continuous flow water heater can be installed. If in doubt, consult a licensed gasfitter who will have access to 'Minimum clearances required for balanced flue terminals, fan-assisted flue terminals, room-sealed appliance terminals and openings of outdoor appliances' from AS/NZS 5601.1 (p. 94-95). G Dim. Infinity VT, HD200, EF models Infinity HD250 models A Min.
Rinnai continuous flow water heaters Product specification pages
Rinnai Infinity VT specification summary Rinnai Infinity VT external codes Gas Type VT16 VT20 VT24 VT26 NG INFVT16N INFVT20N INFVT24N INFVT26N LPG INFVT16L INFVT20L INFVT24L INFVT26L Description Continuous flow gas hot water heaters (with inbuilt frost protection), preset to 55 °C, for external domestic applications. Suitable for mains and low pressure systems. Electronic ignition—requires electricity to operate.
Rinnai Infinity VT dimensions (mm) A B I G P H J N F C D L K E O M VT16 VT20 VT24 VT26 VR1620WG VR2024WG VR2426WG VR2626WG A Width 350 350 350 350 B Depth 194 194 194 194 C Height - unit 530 530 530 530 D Height - including brackets 571 571 571 571 E Hot water outlet (from wall) 87 87 87 87 F Hot water outlet (from centre) 105 105 105 105 G Cold water inlet (from wall) 68 68 68 68 H Cold water inlet (from centre) 10 10 10 10 I Gas connection (from w
Rinnai Infinity VT accessories summary Water Heater On/Off RINNAI Temp. Volume Max Temp. Maintenance Entry Controllers MC Compact Controller Kitchen Deluxe Controller Bathroom Deluxe Controller Pipe Cover Flue Diverters Security Bracket No. 1 No. 2 No.
Controllers A maximum of four water controllers can be fitted, and any combination of the deluxe, compact, and wireless controllers can be used with the following limitations: -- Only ONE master controller can be installed, this can be a Kitchen Deluxe, Compact, or Wireless Controller -- Up to TWO Bathroom Deluxe controllers can be installed -- The fourth controller in any installation must be a Compact or Wireless Controller Each remote controller can be individually programmed, however the water heater ca
Rinnai Infinity HD specification summary Rinnai Infinity HD codes Gas Type HD200 external HDi200 internal HD250 external NG INFHD200HNCN INFHD200FFNCFN INFHD250HNCN LPG INFHD200HNCL INFHD200FFNCFL INFHD250HNCL Description Continuous flow gas hot water heaters (with inbuilt frost protection) for domestic and commercial applications. Suitable for mains and low pressure systems. Electronic ignition—requires electricity to operate.
Rinnai Infinity HD dimensions (mm) A B I G P J H N F C D L K E O M HD200 external VRM2632WC HDi200 internal VR2632FFUC HD250 external VR3237WG A Width 350 350 470 B Depth 250 235~275 244 C Height - unit 600 600 600 D Height - including brackets 636 641 644 E Hot water outlet (from wall) 95 91~131 115 F Hot water outlet (from centre) 110 110 61 G Cold water inlet (from wall) 74 70~110 99 H Cold water inlet (from centre) 27* 27* 52 I Gas connection (from w
Rinnai Infinity HD accessories summary Water Heater On/Off RINNAI Temp. Volume Max Temp. Maintenance Entry Controllers MC Compact Controller Kitchen Deluxe Controller Bathroom Deluxe Controller Flue Diverters Security Bracket HD Error Indication Switch HD200 external No. 1 No. 2 No.
Controllers For domestic applications, a maximum of four water controllers can be fitted, and any combination of the deluxe, compact, and wireless controllers can be used with the following limitations: -- Only ONE master controller can be installed, this can be a Kitchen Deluxe, Compact, or Wireless Controller -- Up to TWO Bathroom Deluxe controllers can be installed -- The fourth controller in any installation must be a Compact or Wireless Controller Each remote controller can be individually programmed,
Rinnai Infinity EF specification summary Rinnai Infinity EF codes Gas Type EF24 external EFi250 internal EF250 external NG EF24NCN INFEF250FFN INFEF250N LPG EF24NCL INFEF250FFL INFEF250L Description High efficiency continuous flow gas hot water heaters (with inbuilt frost protection), preset to 55 °C, for domestic and commercial applications. Suitable for mains and low pressure systems. Electronic ignition—requires electricity to operate.
Rinnai Infinity EF dimensions (mm) A B I G P J H N F C D L K E O M EF24 external K2430WG EFi250 internal KM3237FFUD EF250 external KM3237WD A Width 350 470 470 B Depth 277 257~307 283.1 C Height - unit 600 654 654 D Height - including brackets 644 721.6 721.6 E Hot water outlet (from wall) 164.5 100~140 100 F Hot water outlet (from centre) 100 100 100 G Cold water inlet (from wall) 83 64.6~104 64.6 H Cold water inlet (from centre) 53* 27.7 27.
Rinnai Infinity EF accessories summary Water Heater On/Off RINNAI Temp. Volume Max Temp. Maintenance Entry Controllers MC Compact Controller Kitchen Deluxe Controller Security Bracket Bathroom Deluxe Controller No. 1 No. 2 No.
Controllers For domestic applications, a maximum of four water controllers can be fitted and any combination of the deluxe, compact, and wireless controllers can be used with the following limitations: -- Only ONE master controller can be installed, this can be a Kitchen Deluxe, Compact, or Wireless Controller -- Up to TWO Bathroom Deluxe controllers can be installed -- The fourth controller in any installation must be a Compact or Wireless Controller Each remote controller can be individually programmed, h
Rinnai Infinity internal flueing The Rinnai Infinity internal flueing system is highly versatile and makes installation of an internal water heater simple and convenient. The flueing for internal water heaters is a coaxial design. It is manufactured from a stainless steel inner pipe to discharge products of combustion and a thermoplastic outer pipe for air supply to the appliance.
Rinnai Infinity internal flueing options 1 2 4 3 Direct flueing For installations where the internal Rinnai continuous flow unit is mounted directly on the inside of an external wall, with a maximum wall thickness of: --- 430 mm 485 mm Rinnai Infinity EF models Rinnai Infinity VT and HD models Horizontal extension flueing The same as direct flueing with additional pipe required due to the longer horizontal distance.
Rinnai Infinity internal flue configurations Direct flueing using FFSSKIT For installations where the Rinnai Infinity is mounted directly on the inside of an external wall with a maximum wall thickness of 430 mm (EF models) and 485 mm (VT and HD models). FFSSKIT contains: -- 90 ° bend -- horizontal flue terminal—can be cut to size -- wall trim rubber—white (internal) -- wall trim rubber—black (external) 430 mm max. Infinity EF 485 mm max. Infinity VT and HD White wall trim 140 mm hole 430 mm max.
Vertical straight flueing For installations where the Rinnai Infinity needs to be flued vertically through the roof. Additional lengths of FFSSPIPE1000 can be added as required (can be cut to size). Total flue length can be 15 m. FFSSROOFCOWL FFSSPIPE1000 FFSSCOND To sanitary waste A condensate drain is required for flue lengths over 1.5 m (excludes Rinnai Infinity EFi250). Combination flueing - vertical and horizontal Combination of both vertical and horizontal flueing.
953 ± 5 mm Rinnai Infinity internal flueing components 45 ° bend Code = FFSSBEND90 Code = FFSSBEND45 PVC outer and stainless steel inner. Zero clearance from combustibles. Flue component overlaps by approximately 37 mm. Sold as a pair. PVC outer and stainless steel inner. Zero clearance from combustibles. Flue component overlaps by approximately 37 mm. Roof cowl Condensate trap kit Flue pipe 1000 Code = FFSSROOFCOWL Code = FFSSCOND Code = FFSSPIPE1000 Can be cut to size.
Rinnai continuous flow water heaters Accessories
Rinnai Infinity water controllers Compact Bathroom Deluxe Kitchen Deluxe Wireless BC-100V 97 (mm) 83 83 120 90 120 22 195 128 20 20 Specification summary Codes Compact MC912A Bathroom Deluxe BC100V1Z Kitchen Deluxe MC100V1Z Wireless MC503S (controller) MC503M (transceiver) Compact The smallest, most affordable model. Colour—off white with a grey touch pad. The Compact controller is suitable for use anywhere in the house.
Maximum number of controllers For domestic applications, a maximum of four water controllers can be fitted, and any combination of the deluxe, compact, and wireless controllers can be used with the following limitations: -- Only ONE master controller can be installed, this can be a Kitchen Deluxe, Compact, or Wireless Controller -- Up to TWO Bathroom Deluxe controllers can be installed -- The fourth controller in any installation must be a Compact or Wireless Controller For commercial installations, the Rin
Rinnai Infinity composite recess box Approximate depth with cover on = 240 mm Specification summary Code R1406 Description The Rinnai Composite Recess Box (beige) is an affordable alternative to the Rinnai Metal Recess Box for housing your Rinnai Infinity unit, pipe work and power supply, and can be painted to match your house. The composite recess box enables a Rinnai external continuous flow gas water heater to be partially recessed into an external wall, covered and out of sight.
944 mm Rinnai Infinity metal recess box 417 m 514 m m (R1405 ) m (R 1407 ) 405) m (R1 205 m (R1407) m m 270 Specification summary Codes R1405 R1407 Refer 'Suitable for' to determine what recess box you need. Description The Rinnai Metal Recess Box (white) enables an external continuous flow gas water heater to be recessed (either fully or semi recessed) into an external wall, behind a door and out of sight. Construction is folded galvanised steel, powder coated white.
Rinnai Infinity pipe covers W H1 H2 D Specification summary Codes R1385 R1402SC R1408 R1408SC R1409 Refer 'Suitable for' to determine what recess box you need. Description If you want a clean smooth finish to the installation, the Rinnai Infinity Pipe Cover can be used to cover pipes, valves, and even the external power point. If the power point is located inside the cover it must comply with AZ/NZS Wiring rules. Suitable for R1385 (white) Suitable for VT16, VT20, VT24, and VT26.
Rinnai Infinity security bracket Wall Security bracket Water heater bracket Security bracket Specification summary Code ACC1395 Description A sturdy security bracket can be installed to act as a permanent deterrent to thieves. Consisting of two U-shaped 2 mm powder coated galvanised steel plates which easily interlock through the lower bracket, this system can be easily secured with a robust padlock (not included).
Rinnai Infinity sideways flue diverter Conventional terminal Flue products direction of discharge Conventional terminal with sideways flue diverter Specification summary Codes -- FDS16 Suitable for VT16. -- FDS20 Suitable for VT20. -- FDS24 Suitable for VT24 and VT26.
Rinnai Infinity upwards flue diverter Specification summary Codes -- FDU16 Suitable for VT16. -- FDU20 Suitable for VT20. -- FDU24 Suitable for VT24, and VT26. -- FDU32 Suitable for HD250. Description The Rinnai Infinity Upwards Flue Diverter is an accessory that can be fitted to an external Rinnai continuous flow water heater. It is designed to expel combustion products in a upwards direction.
Rinnai Infinity HD error switch Specification summary Code R1070 Description The Rinnai Infinity HD water heater error indication switch is a volt-free, normally open switch. The switch will shift to a closed position when there is an active error in the water heater. The switch is intended to be connected to a monitoring system such as a building management system, or other visual or audible error indication system.
Rinnai Infinity EZ connect cable Specification summary Code REUEZC Description The installation of a Rinnai EZ Connect Cable allows a maximum of two Rinnai Infinity water heaters (specific models only) to be connected together so they function as one large unit. The two water heaters can be installed 5-460 mm apart. The maximum distance of 460 mm is so the cable will reach between the two units, and to prevent temperature fluctuations when the water is turned off and on.
Rinnai Infinity manifolding Specification summary -- REUMSBC2 Joiner for greater than five manifolded Infinity units. Refer to the 'What to use where' table to determine manifolding components required. Description Infinity units can be manifolded together (up to 25) by connecting them together in parallel to enable a greater hot water flow rate than is possible with a single unit. All information is transmitted via communication cables to the slave units.
Rinnai continuous flow water heaters Appendices
Appendix 1: Limited warranty This warranty is applicable to all Rinnai continuous flow water heaters manufactured from 2010 onwards (serial number 09.12-xxxxxx). All terms of the warranty are effective from the date of installation.
General warranty terms Rinnai reserves the right to make modifications and change specifications and its parts without notice. For the purposes of the Consumer Guarantees Act 1993, Rinnai only guarantees the availability of repair facilities and spare parts for the express warranty periods recorded in the ‘Warranty Summary’. 4. The warranty applies only to the components supplied by Rinnai.
Water quality Water quality outside the limits, as set down below, will void this warranty. Water quality tests must be carried out at the customer’s own cost. Rinnai will reimburse any reasonable test costs where water quality is within the limits tabled.
Appendix 2: Water flow and gas usage When calculating the model of Rinnai Infinity required it is important to determine what the incoming water temperature will be. This is usually calculated on the worst case scenario, i.e. in winter.
HD range, temperature preset to 55 ° C or less (mixed water) HD model Approx. min. to max. gas input (MJ/h) HD200 16-195 HDi200 16-195 HD250 20-249 HD200 16-195 HDi200 16-195 HD250 20-249 HD200 16-195 HDi200 16-195 HD250 20-249 HD200 16-195 HDi200 16-195 HD250 20-249 HD200 16-195 HDi200 16-195 HD250 20-249 5 °C temperature rise 10 °C temperature rise L/min L/h Pressure Approx. gas L/min L/h Pressure Approx.
HD range, temperature preset to 75 ° C (unmixed water) HD model Approx. min. to max. gas input (MJ/h) HD200 16-195 HDi200 16-195 HD250 20-249 HD200 16-195 HDi200 16-195 HD250 20-249 HD200 16-195 HDi200 16-195 HD250 20-249 HD200 16-195 HDi200 16-195 HD250 20-249 HD200 16-195 HDi200 16-195 HD250 20-249 HD200 16-195 HDi200 16-195 HD250 20-249 HD200 16-195 HDi200 16-195 HD250 20-249 HD200 16-195 HDi200 16-195 HD250 20-249 5 °C temperature rise 10 °C temperature rise L/min L/h Pressure Approx.
EF range, temperature preset to 55 ° C or less (mixed water) EF model Approx. min. to max. gas input (MJ/h) EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 5 °C temperature rise 10 °C temperature rise L/min L/h Pressure Approx. gas L/min L/h Pressure Approx. gas loss consumption loss consumption through (MJ/h) through (MJ/h) unit (kPa) unit (kPa) 30.
EF range, temperature preset to 75 ° C (unmixed water) EF model Approx. min. to max. gas input (MJ/h) EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 EF24 EF250 EFi250 16-162 10-211 10-211 5 °C temperature rise 10 °C temperature rise L/min L/h Pressure Approx.
VT range, temperature preset to 55 ° C or less (mixed water) 5 °C temperature rise VT Approx. min. to L/min L/h Pressure Approx. gas model max. gas input loss consumption (MJ/h) through (MJ/h) unit (kPa) VT16 10-125 20.0 1200 75 31.0 VT20 13-160 24.0 1440 120 37.2 VT24 13-188 26.0 1560 170 40.3 VT26 13-199 26.0 1560 200 40.3 15 °C temperature rise VT16 10-125 20.0 1200 75 93.0 VT20 13-160 24.0 1440 120 111.6 VT24 13-188 26.0 1560 170 120.9 VT26 13-199 26.0 1560 200 120.
Appendix 3: Commercial sizing guidelines Sizing guidelines for commercial applications when using secondary storage tanks The table below, based on industry experience, provides average hot water demand for various applications.
Appendix 4: LPG gas bottle consumption We often get asked about how long a gas bottle will last when running a gas appliance. Using the calculation below you can work this out yourself. LPG gas bottle energy calculation 1 kg of LPG gas contains 50.4 MJ of energy 1 kW = 3.6 MJ This means that a 45 kg LPG gas bottle has: 45 kg x 50.4 MJ = 2268 MJ This works for the different bottle sizes, here are the most common: 9 kg = 453.
Appendix 5: Gas boosted solar In New Zealand, solar systems will need boosting unless you are willing to run out of hot water. A gas boosted system is best because it only works when you need hot water that your solar system can't supply. How a gas boosted system works 1. The sun's rays heat water in the solar panels for free. 2. Hot water from the panels is stored in the tank. 3. If the water is too cold, the Rinnai Infinity gas booster heats the water on demand as it travels from the tank to your tap.
Experience our innovation Rinnai.co.nz 0800 746 624 http://www.youtube.