Installation guide

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 25
Controllers
For domestic applications, a maximum of four water controllers can be fitted, and any combination of the deluxe,
compact, and wireless controllers can be used with the following limitations:
- Only ONE master controller can be installed, this can be a Kitchen Deluxe, Compact, or Wireless Controller
- Up to TWO Bathroom Deluxe controllers can be installed
- The fourth controller in any installation must be a Compact or Wireless Controller
Each remote controller can be individually programmed, however the water heater can only deliver one set
temperature at any time. For example, John is in the shower and has set the controller to 42 °C, Jane uses the
kitchen tap at the same timethe water temperature coming out of the kitchen tap will also be 42 °C (or lower if
using a mixer and adding cold water). Jane can only change the programmed temperature once John is out of the
shower.
For commercial installations, the Rinnai Compact Controller can be used as a diagnostic tool.
All wired controllers come with 15 m of cable.
If ordering a wireless controller you will need to order the controller, and the transceiver. Up to four Wireless
Controllers can be attached to one Wireless Transceiver.
Security bracket
Ideal for all Rinnai continuous flow gas water heaters—can be retrofitted to existing installations, and can be easily
installed by the homeowner, gasfitter, or builder.
Metal recess box
Designed for new build installations or major renovations as installation needs to commence during the framing
stage, before internal linings, claddings or building wrap is applied.
The Metal Recess Box can be fully or semi recessed into an external wall.
HD error indication switch
Intended to be connected to a monitoring system such as a BMS (building maintenance system) or other visual or
audible error indication system.
Pipe covers
The HD pipe covers will match the colour of the unitthey are not white as shown in the thumbnail image.
Upwards flue diverter
Suitable for externally mounted Rinnai Infinity continuous flow water heaters NOT installed in a recess box.
Rinnai Innity HD service & maintenance
For reliable operation Rinnai continuous flow water heaters in domestic applications should be
serviced every two years (including inspection of the flue system if installed).
For commercial applications Rinnai has a recommended 'Commercial Maintenance and Servicing
Schedule'. This is available on request or via our websites www.rinnai.co.nz, or
www.rinnai.co.nz/tradesmart.