Installation guide

34 | Rinnai Continuous Flow Water Heating Specication Guide 02-13
Rinnai Innity internal ueing components
953 ± 5 mm
483 ± 5 mm
Stainless steel inner
protrudes 10 ± 2 mm
Flue pipe clamp
Roof cowl
Code = FFSSROOFCOWL
Can be cut to size. Includes two black
injection pipe sections for covering
and protecting the white flue pipe from
UV damage.
90 ° bend
Code = FFSSBEND90
PVC outer and stainless steel inner.
Zero clearance from combustibles. Flue
component overlaps by approximately
37 mm.
45 ° bend
Code = FFSSBEND45
Sold as a pair. PVC outer and stainless
steel inner. Zero clearance from
combustibles. Flue component
overlaps by approximately 37 mm.
Condensate trap kit
Code = FFSSCOND
Required for vertical flue lengths over
1.5 m (excludes Rinnai Infinity EFi250).
Flue pipe 1000
Code = FFSSPIPE1000
Can be cut to size. Includes Munzing
Ring (not pictured). PVC outer and
stainless steel inner. Zero clearance
from combustibles. Flue component
overlaps by approximately 37 mm.
Direct flue kit
Code = FFSSKIT
Can be cut to size. Includes Munzing
Ring (not pictured). Terminal protrudes
approximately 175 mm from the wall.
778 ± 10 mm
480 ± 5 mm
120 ± 5 mm
Generic notes on flueing components
- Flue dimensions:
• inner = 75 mm
• outer = 125 mm
- Construction, PVC outer and stainless steel inner.
- All flue components have zero clearance from combustibles.
- Pipes overlap by approximately 37 mm—once joined the effective length
reduces by 37 mm, this needs to be factored when cutting to size.
- The roof cowl comes with two black UV injection moulded pipe sections for
covering and protecting the white flue pipe from UV damage. If for some
reason any remaining white pipe is exposed to UV, this should be painted
with a suitable UV resistant coating.