Installation guide

Rinnai Continuous Flow Water Heating Specication Guide 02-13 | 37
Maximum number of controllers
For domestic applications, a maximum of four water controllers can be fitted, and any combination of the deluxe,
compact, and wireless controllers can be used with the following limitations:
- Only ONE master controller can be installed, this can be a Kitchen Deluxe, Compact, or Wireless Controller
- Up to TWO Bathroom Deluxe controllers can be installed
- The fourth controller in any installation must be a Compact or Wireless Controller
For commercial installations, the Rinnai Compact Controller can be used as a diagnostic tool.
All wired controllers come with 15 m of cable.
If ordering a wireless controller you will need to order the controller, and the transceiver. Up to four Wireless
Controllers can be attached to one Wireless Transceiver.
Each remote controller can be individually programmed, however the water heater can only deliver one set
temperature at any time. For example, John is in the shower and has set the controller to 42 °C, Jane uses the
kitchen tap at the same timethe water temperature coming out of the kitchen tap will also be 42 °C (or lower if
using a mixer and adding cold water). Jane can only change the programmed temperature once John is out of the
shower.
Positioning
Water controllers are water resistant, however durability is improved when positioned outside the shower recess.
All controllers must be installed at least 400 mm above the highest part of the sink, basin, or bath.
Solar, and Rinnai iHeat installations - controllers are not suitable
Rinnai water controllers cannot be used with Rinnai Infinity units connected to solar systems, or when a Rinnai
iHeat is installed as the preset dip switch setting on the Rinnai Infinity is adjusted from 55 °C to 75 °C.