Rinnai Innity sideways ue diverter
Specification summary
Codes
- FDS16
Suitable for VT16.
- FDS20
Suitable for VT20.
- FDS24
Suitable for VT24 and VT26.
Description
The Rinnai Infinity Sideways Flue
Diverter is an accessory that can
be fitted to an external Rinnai
continuous flow water heater. It
is designed to expel combustion
products in a sideways direction.
Specific applications
Noise reduction, in particular with
larger Infinity models where the unit
is positioned close to a neighbouring
property.
Where there may be an obstruction
such as a tree, fence wall or other
structure, that even though the
Infinity is installed with the required
clearances, will perform more
efficiently if the flue gases are cleared
away from the obstruction.
Where clearance to an openable
window or other building structure is
tight, the clearance shifts to the point
of discharge (close to the edge of the
water heater case).
Suitability
- Externally mounted Rinnai
Infinity continuous flow water
heaters NOT installed in a recess
box
- External SINGLE water heater
applications only
- Balconies, patios, or other
enclosed areas where all flue
products are expelled FREELY
into an above open-air situation
with natural ventilation, without
stagnant areas, where products
of combustion are rapidly
dispersed by wind and natural
convection
Dimensions
Height: 385 mm
Width: 140 mm
Depth: 60 mm
Important
The flue diverter MUST remain as a
permanent fixture as removal could
mean the water heater position no
longer complies with AS/NZS 5601.1.
Conventional
terminal
Conventional
terminal with
sideways flue
diverter
Flue products
direction of discharge
Openable
window
j
n
Sideways flue
diverter—ensure
1500 mm clearance
j and n relate to minimum clearancs required for
balanced flue terminals from AS/NZS 5601.1