Installation guide

56 | Rinnai Continuous Flow Water Heating Specication Guide 02-13
VT range, temperature preset to 55 °C or less (mixed water)
5 °C temperature rise 10 °C temperature rise
VT
model
Approx. min. to
max. gas input
(MJ/h)
L/min L/h Pressure
loss
through
unit (kPa)
Approx. gas
consumption
(MJ/h)
L/min L/h Pressure
loss
through
unit (kPa)
Approx. gas
consumption
(MJ/h)
VT16 10-125 20.0 1200 75 31.0 20.0 1200 75 62.0
VT20 13-160 24.0 1440 120 37. 2 24.0 1440 120 74.4
VT24 13-188 26.0 1560 170 40.3 26.0 1560 170 80.6
VT26 13-199 26.0 1560 200 40.3 26.0 1560 200 80.6
15 °C temperature rise 20 °C temperature rise
VT16 10-125 20.0 1200 75 93.0 20.0 1200 75 124.0
VT20 13-160 24.0 1440 120 111.6 24.0 1440 120 148.8
VT24 13-188 26.0 1560 170 120.9 26.0 1560 170 161.2
VT26 13-199 26.0 1560 200 120.9 26.0 1560 200 161.2
25 °C temperature rise 30 °C temperature rise
VT16 10-125 16.0 960 75 125.0 13.3 800 60 125.0
VT20 13-160 20.0 1200 120 160.0 16.7 1000 87 160.0
VT24 13-188 24.0 1440 140 188.0 20.0 1200 100 188.0
VT26 13-199 26.0 1560 200 199.0 21.7 1300 200 199.0
35 °C temperature rise 40 °C temperature rise
VT16 10-125 11.4 686 44 125.0 10.0 600 35 125.0
VT20 13-160 14.3 857 64 160.0 12.5 750 50 160.0
VT24 13-188 17.1 1029 70 188.0 15.0 900 55 188.0
VT26 13-199 18.6 1114 130 199.0 16.3 975 95 199.0
45 °C temperature rise 50 °C temperature rise
VT16 10-125 8.9 533 29 125.0 8.0 480 24 125.0
VT20 13-160 11.1 667 42 160.0 10.0 600 35 160.0
VT24 13-188 13.3 800 40 188.0 12.0 720 40 188.0
VT26 13-199 14.4 867 80 199.0 13.0 780 70 199.0