Installation guide

6 | Rinnai Continuous Flow Water Heating Specication Guide 02-13
Continuous ow summary table
Model Mounting
position
Application suitability Energy
star rating
Input Output Thermal
eff. on
high
Status
monitor
Infinity VT16 External Domestic 6.2 125 MJ/h or 35 kW 29.6 kW 81% No
Infinity VT20 External Domestic 5.9 160 MJ/h or 44 kW 34.9 kW 80% No
Infinity VT24 External Domestic 5.8 188 MJ/h or 52 kW 42.1 kW 80% No
Infinity VT26 External Domestic 5.8 199 MJ/h or 55 kW 44.2 kW 80% No
Infinity HD200 External Domestic and commercial 5.9 199 MJ/h or 55 kW 47.0 kW 82% Yes
Infinity HDi200 Internal Domestic and commercial 6.1 195 MJ/h or 54 kW 45.1 kW 83% No
Infinity HD250 External Domestic and commercial 5.6 249 MJ/h or 69 kW 59.9 kW 81% No
Infinity EF24 External Domestic and commercial 6.8 162 MJ/h or 45 kW 43.0 kW 95% No
Infinity EF250 External Domestic and commercial 6.8 211 MJ/h or 58.6 kW 55.6 kW 95% Yes
Infinity EFi250 Internal Domestic and commercial 6.8 211 MJ/h or 58.6 kW 55.6 kW 95% Yes
Water delivery at a
25 °C rise
16 L 20 L 24 L 26 L 32 L
External models
High
efficiency
Standard
efficiency
Internal models
High
efficiency
Standard
efficiency