User manual

32/85 V 1.0
49 Remote control unit Swing pro 350 only
The optional available remote control unit enables remote control of the inverter. The remote control unit must be
connected to the remote port located on the rear side of the inverter. When using the remote control unit the main
switch of the inverter must be in the “ON” position.
Remote port
50 Operation
The Inverter is controlled by a single switch located on the front panel of the inverter.
Engaging
Switch to “ON-Position“. The green Power LED will illuminate and you will hear three beep.
The Inverter is ready to use.
Power down
Switch to „OFF-Position“. All LED’s are dark. The inverter is OFF.
Remark
Even if the inverter is switched to off, it is not disconnected from the battery. It still draws very little power from the
battery. If you don’t need the inverter for an extended period disconnect it from the battery to avoid low discharge
of battery.
51 LED-Indicator
51.1 Overload protection LED : (OLP)
The overload indicator indicates that the power inverter has shut itself down. When output voltage over continue
power, then must return to operate manually.
51.2 Over voltage protection LED: (OVP)
The over voltage indicator indicates that the power inverter has shut itself down because its input voltage
exceeded the maximum input voltage.
51.3 Under voltage protection LED: (UVP)
The under voltage indicator indicates that the power inverter has shut itself down because its input voltage fell
below minimum input voltage.
51.4 Over temp protection LED : (OTP)
The over temp indicator indicates that the power inverter has shut itself down because its temp has become
overheated. The power inverter may overheat because it has been operated at power levels above its rating, or
because it has been installed in a location which does not allow it to dissipate heat properly. The power inverter
will automatically back up, once it has cooled off.