User manual

40/85 V 1.0
59.2 AC-Wiring
HIPHOP pro 1500 & HIPHOP pro 2000
Use the included AC-Connector or use ring terminal to assemble AC-Cables to connect the AC-Load to the output
of inverter.
HIPHOP pro 3000
Even the inverter is protected against overload and short circuit, we recommend to use an AC-Circuit breaker of
correct size.
For safe operation it is necessary to connect earth (PE) and neutral (N) of the inverter output to central ground of
the inverter.
Even more safe is to use a 15mA or 30mA earth leakage switch in the AC-Installation.
59.3 Grounding
The earth wire protection is only possible if the inverter enclosure is also connected to earth. Use a . 8-10mm2
cable (AWG 8) and connect it to the earth terminal of the inverter. This is also important for lighting protection.
Do not operate the power inverter without connecting it to Ground.
Electrical shock hazard may result.
60 Remote control unit
The optional available remote control unit enables remote control of the inverter. The remote control unit must be
connected to the remote port (RS-232 connector) located on the rear side of the inverter. Before using the remote
control unit the main switch of the inverter must be in the “ON” position.
To connect the AC-wire, open the
front plate (6 screws).
Pull the AC-wire through the cord grip of the
front plate and connect it to the AC-clamps.
L = Phase, N = Neutral, Ground
Close the front plate with the screws and
secure the AC-wire by cord grip.