Quick Start Manual

W
R A
Motor Valve
PG 22
W RH [A?] 3 Zoned Hot Water - Motor Valve
Step 1 - based on your valve type
Motor driven Valve- Connect the R (or RH) wire to the RH
terminal on the 6030. Connect the W wire to the W terminal
on the 6030. Connect the remaining wire to the A terminal.
Solenoid valve -Connect the R (or RH) wire to the RH
terminal on the 6030. Connect the W wire to the A terminal
on the 6030. Connect the remaining wire to the W terminal.
STEP 2 - Set Config jumpers per this diagram.
Your system is now connected to the 6030.
 Please Go T o Page 9
WIRES
STEP 1 - Connect the W wire to the W terminal and W2 to
W2 on the 6030. This connects 2 stages of heat.
STEP 2 - Connect the Y wire to the Y terminal and Y2 wire
to Y2 on the 6030. This connects 2 stages of cool.
STEP 3 - Connect the RH or R wire to the RH terminal on
the thermostat. This connects the Heater/Cooler Power.
STEP 4 - Connect the G wire to the G terminal on the
Thermostat. This connects to the Fan.
STEP 5 - Set Config jumpers per this diagram. If you
have Electric heat set 4, if you have Gas or Oil set 5.
Your HVAC system is now connected
to the 6030.
Please Go To Page 9
W2 W Y Y2 RH G
PG 21
2 Stage Heat and Cool
6030
Terminals
6030
Terminals
Y2
W2
W
Y
RH
RC
G
C
HVAC SYSTEM
OPTIONAL
POWER
WIRES
C B O
W2
W
Y Y2 RH RC G A
C B O
W2
W
Y Y2 RH RC G A
SET JUMPERS
SET JUMPERS
or
1 2 4 5
3
B
A
1 2 4 5
3
B
A