Quick Start Manual
W
R A
Motor Valve
PG 22
W RH [A?] 3 Zoned Hot Water - Motor Valve
Step 1 - based on your valve type
Motor driven Valve- Connect the R (or RH) wire to the RH
terminal on the 6030. Connect the W wire to the W terminal
on the 6030. Connect the remaining wire to the A terminal.
Solenoid valve -Connect the R (or RH) wire to the RH
terminal on the 6030. Connect the W wire to the A terminal
on the 6030. Connect the remaining wire to the W terminal.
STEP 2 - Set Config jumpers per this diagram.
Your system is now connected to the 6030.
Please Go T o Page 9
WIRES
STEP 1 - Connect the W wire to the W terminal and W2 to
W2 on the 6030. This connects 2 stages of heat.
STEP 2 - Connect the Y wire to the Y terminal and Y2 wire
to Y2 on the 6030. This connects 2 stages of cool.
STEP 3 - Connect the RH or R wire to the RH terminal on
the thermostat. This connects the Heater/Cooler Power.
STEP 4 - Connect the G wire to the G terminal on the
Thermostat. This connects to the Fan.
STEP 5 - Set Config jumpers per this diagram. If you
have Electric heat set 4, if you have Gas or Oil set 5.
Your HVAC system is now connected
to the 6030.
Please Go To Page 9