Quick Start Manual
PG 15
2 WIRE HEAT
Heating GAS MILLIVOLT or 24vac
NOTE: Wires marked with
dotted line are optional.
PG 16
3 Wire Heat
6030
W
R
C
GAS Milivolt Heat
C B O
W2
W
Y Y2 RH RC G A
C B O
W2
W
Y Y2 RH RC G A
6030
W
R G
C
HVAC SYSTEM
STEP 1 - Connect the R (or RH) wire to the RH
terminal
on
the 6030. This connects the Heater Power to the thermostat.
STEP 2 - Connect the W wire to the W on the 6030.
This connects the heater control line to the 6030.
STEP 3 - Set Config jumpers per this diagram.
Your Heater is now connected to the 6030.
Please Go To Page 9
STEP 1 - Connect the R (or RH) wire to the RH terminal
on the 6030. This connects to the Heater Power .
STEP 2 - Connect the W wire to the W terminal on the
6030. This connects the heater control line to the 6030.
STEP 3 - Connect the G wire to the G terminal on the
thermostat. This connects the Fan to the 6030
STEP 4 - Set Config jumpers per this diagram. If you
have Electric heat set 4, if you have Gas or Oil set 5.
Your system is now connected to the 6030.
Please Go To Page 9
OPTIONAL POWER
OPTIONAL POWER
WIRES WIRES
SET
JUMPERS
SET JUMPERS