Instruction manual

6. CC-Link COMMUNICATION
IMR01Y06-E6
23
Error flag/Error reset processing
If the Error reset request flag [RY(n+1)A] is turned on while the Error status flag [RX(n+1)A] is
turned on, the Error status flag history is cleared and the flag [RX(n+1)A] turns off.
Error status flag
[RX(n+1)A]
Error reset
request flag
[RY(n+1)A]
Remote ready
[RX(n+1)B]
ON
OFF
ON
OFF
ON
OFF
Extension number for display selection processing
The content of the extended display remote register is selected.
After the Extension number for display [RYn0 to RYn5] is set, turn on the Extended display flag
[RYnC]. After the data in the Remote register [RWrn to RWrn+3] is displayed, check that Extended
display completion [RXnC] is turned on and then turn off the Extended display flag [RYnC]. If the
extended display flag is turned off, the extended display completion is turned off.
Extension number
for display
[RYn0 to RYn5]
Extended display flag
[RYnC]
Extended display
completion
[RXnC]
Remote register
[RWrn to RWrn+3]
ON
OFF
ON
OFF
ON
OFF
ON
OFF
(R/O data: Automatically updated)
Extension number 0
Extension number 0
Extension number 1
Extension number 1