Specifications

Temperature Controller Driver
GP-Pro EX Device/PLC Connection Manual
231
continued to next page
Address Identifier
Description
Address Identifier
Description
64 HA Event 1 differential gap 93 OL Output limiter (low) [heat-side]
65 TD Event 1 delay timer 94 PX
Output change rate limiter (up) [cool-side]
66 OA Force ON of Event 1 action 95 PY
Output change rate limiter (down) [cool-side]
67 XB Event 2 type 96 OX Output limiter (high) [cool-side]
68 FB Event 2 channel setting 97 OY Output limiter (low) [cool-side]
69 WB Event 2 hold action 98 GB AT bias
6A LG Event 2 interlock 99 G3 AT cycles
6B HB Event 2 differential gap 9A OP Output value with AT turned on
6C TG Event 2 delay timer 9B OQ Output value with AT turned off
6D OB Force ON of Event 2 action 9C GH AT differential gap time
6E XC Event 3 type 9D KC
Proportional band adjusting factor [heat-side]
6F FC Event 3 channel setting 9E KD Integral time adjusting factor [heat-side]
70 WC Event 3 hold action 9F KE
Derivative time adjusting factor [heat-side]
71 LH Event 3 interlock A0 KF Proportional band adjusting factor [cool-side]
72 HC Event 3 differential gap A1 KG Integral time adjusting factor [cool-side]
73 TE Event 3 delay timer A2 KH
Derivative time adjusting factor [cool-side]
74 OC Force ON of Event 3 action A3 P6
Proportional band limiter (high) [heat-side]
75 XD Event 4 type A4 P7
Proportional band limiter (low) [heat-side]
76 FD Event 4 channel setting A5 I6
Integral time limiter (high) [heat-side]
77 WD Event 4 hold action A6 I7
Integral time limiter (low) [heat-side]
78 LI Event 4 interlock A7 D6
Derivative time limiter (high) [heat-side]
79 HD Event 4 differential gap A8 D7
Derivative time limiter (low) [heat-side]
7A TF Event 4 delay timer A9 P8
Proportional band limiter (high) [cool-side]
7B OD Force ON of Event 4 action AA P9
Proportional band limiter (low) [cool-side]
7C XS CT ratio AB I8
Integral time limiter (high) [cool-side]
7D ZF CT assignment AC I9
Integral time limiter (low) [cool-side]
7E ND Heater break alarm (HBA) type AD D8
Derivative time limiter (high) [cool-side]
7F DH
Number of heater break alarm (HBA) delay times
AE D9
Derivative time limiter (low) [cool-side]
80 XN Hot/Cold start AF V2 Open/Close output neutral zone
81 SX Start determination point B0 SY
Action at feedback resistance (FBR)
input error
82 XL SV tracking B1 FV Feedback adjustment
83 OT MV transfer function B2 TN Control motor time
84 XE Control action B3 OI Integrated output limiter
85 PK
Integral/derivative time decimal point position
B4 VS Valve action at STOP
86 KA
Derivative action
B5 KI ST proportional band adjusting factor
87 KB Undershoot suppression factor B6 KJ
ST integral time adjusting factor
88 DG Derivative gain B7 KK ST derivative time adjusting factor
89 IV ON/OFF action differential gap (upper) B8 SU ST start condition
8A IW ON/OFF action differential gap (lower) B9 Y7 Automatic temperature rise group
8B WH Action (high) at input error BA RT Automatic temperature rise dead time
8C WL Action (low) at input error BB R2 Automatic temperature rise gradient data
8D OE Manipulated output value at input error BC NS EDS transfer time decimal point position
8E OF
Manipulated output value at STOP mode
[heat-side]
BD NV Output average processing time for EDS
8F OG
Manipulated output value at STOP mode
[cool-side]
BE NW Responsive action trigger point for EDS
90 PH
Output change rate limiter (up) [heat-side]
BF HU Setting change rate limiter unit time
91 PL
Output change rate limiter (down) [heat-side]
C0 RU Soak time unit
92 OH Output limiter (high) [heat-side] C1 SH Setting limiter (high)