Specifications

Temperature Controller Driver
GP-Pro EX Device/PLC Connection Manual
238
<Communication identifier list>
continued to next page
Address Identifier
Description
Address Identifier
Description
00 VR ROM version (Z-COM module) 21 VT PLC scanning time
01 VR ROM version (Z-COM module) 22 R5 PLC communication start time
02 VQ ROM version (Function module) 23 RY
Method for setting the number of con-
nected modules
03 VQ ROM version (Function module) 24 RK Slave mapping method
04 UT
Integrated operating time monitor (Z-
COM module)
25 QY
Number of connected modules (Z-TIO
module)
05 UV
Integrated operating time monitor
(Function module)
26 QU
Number of connected modules (Z-DIO
module)
06 ER Error code (Z-COM module) 27 QO
Number of connected modules (Z-CT
module)
07 EZ Error code (Function module) 28 QA Number of valid groups
08 EM
Backup memory state monitor (Z-COM
module)
29 X2
Control RUN/STOP holding setting
(Each unit)
09 CZ
Backup memory state monitor (Function
module)
2A M1 Measured value (PV)
0A QM
System communication state
2B AJ Comprehensive event state
0B QL SRZ normal communication flag 2C L0 Operation mode state monitor
0C ES PLC communication error code 2D O1
Manipulated output value (MV) monitor
[heat-side]
0D QN Unit recognition flag 2E O2
Manipulated output value (MV) monitor
[cool-side]
0E QK
Monitor for the number of connected
modules
2F M3
Current transformer (CT) input value
monitor
0F SR RUN/STOP transfer (Each unit) 30 MS Set value (SV) monitor
10 SW RUN/STOP transfer (Each module) 31 S2 Remote setting (RS) input value monitor
11 X1
Control RUN/STOP holding setting (Each
module)
32 B1 Burnout state monitor
12 VK Communication 1 protocol 33 AA Event 1 state monitor
13 VL
Communication 1 communication speed
34 AB Event 2 state monitor
14 VM
Communication 1 data bit configuration
35 AC Event 3 state monitor
15 VN
Communication 1 interval time
36 AD Event 4 state monitor
16 VP Communication 2 protocol 37 AE Heat break alarm (HBA) state monitor
17 VU
Communication 2 communication speed
38 Q1 Output state monitor
18 VW
Communication 2 data bit configuration
39 TR Memory area soak time monitor
19 VX
Communication 2 interval time
3A Hp
Holding peak value ambient temperature
monitor
1A QV Station number 3B ED Logic output monitor 1
1B QW PC number (CPU No.) 3C EE Logic output monitor 2
1C QZ Register type 3D G1 PID/AT transfer
1D QS Register start number (High-order 4-bit) 3E J1 Auto/Manual transfer
1E QX Register start number (Low-order 16-bit) 3F C1 Remote/Local transfer
1F QQ System data address bias 40 ZA Memory area transfer
20 QT COM module link recognition time 41 AR Interlock release