Specifications

Temperature Controller Driver
GP-Pro EX Device/PLC Connection Manual
240
continued to next page
Address Identifier
Description
Address Identifier
Description
A0 XS CT ratio C8 P7
Proportional band limiter (low) [heat-side]
A1 ZF CT assignment C9 I6
Integral time limiter (high) [heat-side]
A2 ND Heater break alarm (HBA) type CA I7
Integral time limiter (low) [heat-side]
A3 DH
Number of heater break alarm (HBA)
delay times
CB D6 Derivative time limiter (high) [heat-side]
A4 XN Hot/Cold start CC D7 Derivative time limiter (low) [heat-side]
A5 SX Start determination point CD P8
Proportional band limiter (high) [cool-side]
A6 XL SV tracking CE P9
Proportional band limiter (high) [cool-side]
A7 OT
MV transfer function
CF I8
Integral time limiter (high) [cool-side]
A8 XE Control action D0 I9
Integral time limiter (low) [cool-side]
A9 PK
Integral/derivative time decimal point
position
D1 D8 Derivative time limiter (high) [cool-side]
AA KA Derivative action D2 D9 Derivative time limiter (low) [cool-side]
AB KB Undershoot suppression factor D3 V2 Open/Close output neutral zone
AC DG
Derivative gain
D4 SY
Action at feedback resistance (FBR)
input error
AD IV ON/OFF action differential gap (upper) D5 FV Feedback adjustment
AE IW ON/OFF action differential gap (lower) D6 TN Control motor time
AF WH Action (high) at input error D7 OI Integrated output limiter
B0 WL Action (low) at input error D8 VS Valve action at STOP
B1 OE
Manipulated output value at input error
D9 KI ST proportional band adjusting factor
B2 OF
Manipulated output value at STOP mode
[heat-side]
DA KJ ST integral time adjusting factor
B3 OG
Manipulated output value at STOP mode
[cool-side]
DB KK ST derivative time adjusting factor
B4 PH
Output change rate limiter (up) [heat-side]
DC SU ST start condition
B5 PL
Output change rate limiter (down) [heat-side]
DD Y7 Automatic temperature rise group
B6 OH Output limiter (high) [heat-side] DE RT Automatic temperature rise dead time
B7 OL Output limiter (low) [heat-side] DF R2 Automatic temperature rise gradient data
B8 PX
Output change rate limiter (up) [cool-side]
E0 NS EDS transfer time decimal point position
B9 PY
Output change rate limiter (down) [cool-side]
E1 NV Output average processing time for EDS
BA OX Output limiter (high) [cool-side] E2 NW Responsive action trigger point for EDS
BB OY Output limiter (low) [cool-side] E3 HU Setting change rate limiter unit time
BC GB AT bias E4 RU Soak time unit
BD G3 AT cycles E5 SH Setting limiter (high)
BE OP Output value with AT turned on E6 SL Setting limiter (low)
BF OQ Output value with AT turned off E7 TS PV transfer function
C0 GH AT differential gap time E8 EA
Operation mode assignment 1 (Logic output
selection function) Logic output 1 to 4
C1 KC
Proportional band adjusting factor [heat-side]
E9 EB
Operation mode assignment 2 (Logic output
selection function) Logic output 5 to 8
C2 KD Integral time adjusting factor [heat-side] EA KM SV select function
C3 KE
Derivative time adjusting factor [heat-side]
EB MC
Remote SV function master channel
module address
C4 KF
Proportional band adjusting factor [cool-side]
EC MN
Remote SV function master channel
selection
C5 KG Integral time adjusting factor [cool-side] ED DY
Output distribution master channel mod-
ule address
C6 KH
Derivative time adjusting factor [cool-side]
EE DZ
Output distribution master channel selec-
tion
C7 P6
Proportional band limiter (high) [heat-side]
EF RL Address of interacting modules