Specifications

Temperature Controller Driver
GP-Pro EX Device/PLC Connection Manual
241
Address Identifier
Description
Address Identifier
Description
F0 RM Channel selection of interacting modules 10A VF Z-DIO Interval time
F1 RN Selection switch of interacting modules 10B M4
Current transformer (CT) input value monitor
F2 VG TIO Interval time 10C M5 Load factor conversion CT monitor
F3 L1 Digital input (DI) state 1 10D AF Heater break alarm (HBA) state monitor
F4 L6 Digital input (DI) state 2 10E AG Heater overcurrent alarm state monitor
F5 Q2 Digital output (DO) state 1 10F CJ Automatic setting state monitor
F6 Q3 Digital output (DO) state 2 110 BT
Heater break/Heater overcurrent alarm
automatic setting selection
F7 Q4 DO manual output 1 111 BU Automatic setting transfer
F8 Q5 DO manual output 2 112 A8 Heater break alarm (HBA) set value
F9 DO DO output distribution selection 113 BZ Heater break alarm (HBA) selection
FA O8 DO output distribution bias 114 A6 Heater overcurrent alarm set value
FB O9 DO output distribution ratio 115 BO Heater overcurrent alarm selection
FC V0 DO proportional cycle time 116 CX
Heater break alarm (HBA) interlock release
FD VJ
DO minimum ON/OFF time of propor-
tioning cycle
117 CY
Heater overcurrent alarm interlock release
FE H2 DI function assignment 118 LK Set lock
FF E1 Memory area setting signal 119 BV CT type
100 LQ
DO signal assignment module address 1
11A XT CT ratio (CT number of winds)
101 LR
DO signal assignment module address 2
11B DI
Number of heater break alarm (HBA)
delay times
102 LT DO output assignment 1 [DO1 to DO4] 11C BW
Automatic setting factor for heater break
alarm (HBA)
103 LX DO output assignment 2 [DO5 to DO8] 11D B9
Automatic setting factor for heater over-
current alarm
104 NB DO energized/de-energized 11E BP
Determination current value for auto-
matic setting
105 DD
DO output distribution master channel
module address
11F BQ Automatic setting time
106 DJ
DO output distribution master channel
selection
120 BX
Module address assignments for CT input
107 OJ
DO manipulated output value (MV) at
STOP mode
121 BY
Module channel assignments for CT input
108 D3 DO output limiter (high) 122 IC Load factor conversion method
109 D4 DO output limiter (low) 123 VH CT Interval time
Setting "Use system data area" to GP-Pro EX system area result in improper opera-
tion. Do not set "Use system data area."
System area setting that can be used for the temperature controller is reading area size only.
Please refer to the GP-Pro EX Reference Manual for system data area.
Cf. GP-Pro EX Reference Manual "Appendix 1.4 LS Area (Direct Access Method)"
Please refer to the precautions on manual notation for icons in the table.
)"Manual Symbols and Terminology"
Even if non-existing address is used, there are cases when read error is not indicated. In this
case, zero (0) is kept for read out data. On the other hand, writing error is indicated.