User Manual

8
RND 305-00016 & 305-00017
ModelSBC Ð2110SBC Ð2115SBC - 2120
Output
Absorption Charge Voltage Selections
AGM/GEL : 14.1V WET : 14.4V CALCIUM-CALCIUM : 15.5V
Float Charge Voltage Selections
13.2V, 13.5V, 13.8V
Battery Charger / Power Supply Selections
YesYes Yes
Maximum Output Charging Current (Continuous)
10A15A 20A
Recommended Battery Capacity Range
40 Ð 100AH 60 Ð 150AH 80 - 200AH
Soft Start Bulk Charge
Battery Voltage to Trigger (cut-in) Soft Start
Bulk Charge Mode
<9V
Soft Start Bulk Charge Current (Current Limit)
5A 7.5A 10A
Ripple and Noise (Peak to Peak)
100mV 100mV 150mV
Efficiency at Maximum Power
90% 87%82%
Dual Bank Charging (Battery must be of same type)
No YesYes
Input
AC Voltage Range
18260V 50Hz~
AC Current at Full Load
1.2A 1.8A 3A
Protection
Overload
90-110% Rated Output Current or 50% Rated Output Current (Soft Charge)
Protection Type: Constant Current Limiting, recovers Automatically after
Fault Condition is Removed.
Short Circuit
Recovers Automatically After Fault Condition is Removed
Reverse Polarity
Car Blade Fuse
Over Temperature
Protection Type: Automatically de-rate Charge Current Until Zero or Shut
Down
OVP Output Over Voltage
Yes
CoolingCooling Method
Convection CoolThermostatic, Variable Speed Fan, Fan stops at
Float
Indicators
3 Stage Battery Charger / Power Supply Mode
Yes
Charge Phase Bulk / Absorption / Float
Yes
Fault Mode
Yes
AC Power
Yes
Fuses
AC Fuses at IEC AC Power Socket
T2AT3.15AT5A
DC Car Blade Fuse at Front Panel
20A30A 30A
Accessories
Cable & Spare Fuses
Yes
Remote Temperature Sensor
Optional
Approvals
Safety : EN 60335
Yes
EMC : EN 55014
Yes
Others Dimensions and Weight
160x61x173mm ; 1.3kg 160x61x173mm ; 1.4kg 160x61x207mm ; 1.6kg
RemarksAll values are based on the standard ambient temperature 25¡C and pressure 0.1Mpa.
J. Specifi cations
RND 305-00017 RND 305-00016
40 - 100 Ah
180 - 260 VAC, 50 Hz
25°C