Specifications

4
Hearth
Thehearthshouldbeabletoaccommodatetheweightofthestoveanditschimneyifthechimneyisnot
independentlysupported.Theweightofthestoveisindicatedinthebrochure.
Thestov eshouldalwaysbeinstalledonanoncombustiblehearthofasizeandconstructionthatisin
accordancewiththeprovisionsofthecurrentBuildingRegulationsApprovedDocumentJ.
Theclearancedistancestocombustiblematerialbeneath,surroundingoruponthehearthandwalls
adjacenttothehearthshouldcomplywiththeguidanceontheseparationofcombustiblematerialgivenin
BuildingRegulations ApprovedDocumentJandalsointhesestoveinstructions.
Ifthestoveistobeinstalledonawoodenfloor,itmustbecoveredwithanoncombustiblematerialatleast
12mmthick,inaccordancewithBuildingRegulationsApprovedDocumentJ,t oadistanceof30cminfront
ofthestoveand15cmtoeachsidemeasuringfromthedoorofthecombust ionchamber.
Combustionairsupply
Inorderforthestovetoperformefficientlyandsafelythereshouldbeanadequateairsupplyintotheroom
inwhichthestoveisinstalledtoprovidecombustionair.Thisisparticularlynecessaryiftheroomisdouble
glazedorafluedraughtstabiliserisoperatinginthesameroomastheappliance.Itmaybenecessaryto
increasetheairventsizeinpropertywithlowairpermeability(<5.0m
3
/(h.m
2
).
Theprovisionofairsupplytothestovemustbeinaccordancewit hcurrentBuildi ngRegulationsApproved
DocumentJ.Anopeningwindowisnotappropriateforthispurpose.
Connectiontochimney
Allthestoveshavearearand/ortopfluegasconnectort hatallowsconnectiontoeitheramasonrychimney
oraprefabricatedfactorymadeinsulatedmetalchimneyinaccordancewiththeinstructionsforthe
appliancegivenintheinstructionbooklet.
CarbonMonoxideAlarm
AcarbonmonoxidealarmcomplyingwithBSEN50291mustbefittedinthesameroomastheappliancein
accordancewiththecurrentBuildingRegulationsPartJ.Itshouldbepositionedontheceilingatleast
300mmfromanywallor,ifitislocatedonawall,ashighupaspossible(aboveanydoorsandwindows)but
notwithin150mmoftheceiling.Thealarmshouldalsobebetween1mand3mhorizontallyfromthe
appliance.
Commissioningandhandover
Ensureloosepartsarefittedinaccordancewiththeinstructionsgivenintheinstructionbooklet.
Oncompletionoftheinstallationallowasuitableperiodoftimeforanyfirecementandmortartodryout,
whenasmallfiremaybelitandcheckedtoensurethesmokeandfumesaretakenfromthestoveupthe
chimneyandemittedsafelytoatmosphere.Donotrunatfulloutputforatleast24hours.
Oncompletionoftheinstallationandcommissioningensurethattheoperatinginstructionsforthestoveare
leftwiththecustomer.Ensuretoadvisethecustomeronthecorrectuseoftheappliancewit hthefuelslikely
tobeusedonthestoveandwarnthemtouseonlytherecommendedfuelsforthestove.
Advisetheuserwhattodoshouldsmokeorfumesbeemittedfromthestove.Thecustomershouldbe
warnedtouseafireguardtoBS6539inthepresenceofchildren,agedand/orinfirmpersons.
Page3