Technical data

Fig 5.
Fig 6.
Fig 7.
660.0
560.5
500.0
244.0
46.5
100.0
=
=
GAS SUPPLY PIPE KNOCK OUTS
78.0
4 SPIGOT SCREWS
7
50mm MINIMUM (2in)
5.2.3 REBATED SURROUND INSTALLATION
When fitting the fire to a pre-cast flue it is possible to use a 152mm deep rebated surround. Two optional extras are required as follows: -
Part Number
Closure Plate 989571
Spigot 989568
Fit the closure plate to the wall ensuring that a good seal is made between the plate and the wall. The plate has been designed to sit on the
floor behind the rebated surround or hearth. This will position the spigot opening at the correct height for the spigot when using a 50mm
high hearth. If your hearth is of a different height reposition accordingly.
If using a concealed gas connection ensure it is installed before fitting the closure plate. Knock-outs are provided for gas piping.
Fit the spigot to the rear of the fire using the four screws provided in the screw pack. Refer to Figures 5 and 6. Proceed as follows: -
Position the spigot on the rear of the fire.
Screw from inside the canopy into the spigot. It is easiest to start each screw before tightening fully.
DO NOT FIT THE RESTRICTOR