Specifications

4-6 Courier V.Everything External Modem: Getting Started
Getting Information About Calls
Here are the commands that provide detailed information about
your current settings and current and last calls.
To get call-in-progress data and current settings while you are
on line, set DIP switch 9 OFF and then send ATZ <Enter> (or
power the Courier off and then on).
Alternatively, you can send ATS14.0=0 <Enter>, but be aware
that the DIP switch setting will override your setting at power
on or reset (even if you add &W to write the command to
NVRAM).
Once you’ve set DIP switch 9 or sent ATS14.0=0 <Enter>, you
can type the following command to get to online command
mode, and the Courier will not hang up:
+++
To return on line, type:
ATO <Enter>
Current Settings
Current settings
ATI4
Data or fax mode
AT+FCLASS?
0=Data 1=Class 1 fax 2.0=Class 2.0 fax
Call in Progress
Speed
ATI6 — Speed
Duration
ATI6 — Current Call
Modulation
ATI11 — Modulation
Error control protocol
ATI6 — Protocol
Compression type
ATI6 — Compression
Data or fax mode
AT+FCLASS?
0=Data 1=Class 1 fax 2.0=Class 2.0 fax