Installation Instructions VersaView Industrial Non-display Computers Catalog Numbers 6155R-NSXPH, 6155R-NPXPH, 6155R-7SXPH, 6155R-7S2KH, 6155R-7PXPH, 6155R-7P2KH, 6155R-14SXPH, 6155R-14S2KH, 6155R-14PXPH, 6155R-14P2KH, 6155F-NPXPH, 6155F-NPXPHDC Topic Page Important User Information 2 Environment and Enclosure Information 3 European Union Directive Compliance 4 Operating Systems 5 Multilingual User Interface CD Pack 5 Before You Begin 6 Install the Computer 7 Product Dimensions 14 Connect
VersaView Industrial Non-display Computers Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://literature.rockwellautomation.
VersaView Industrial Non-display Computers 3 Environment and Enclosure Information Review the information on enclosures and environments before installing the product. ATTENTION Environment and Enclosure This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC publication 60664-1), at altitudes up to 2000 m (6561 ft) without derating.
VersaView Industrial Non-display Computers European Union Directive Compliance This product meets the European Union Directive requirements when installed within the European Union or EEA regions and have the CE mark. A copy of the Declaration of Conformity is available at the Rockwell Automation website http://ab.com under Product Certification.
VersaView Industrial Non-display Computers 5 Operating Systems The computers are shipped with one of these operating systems: • Windows 2000 Professional, Service Pack 4 with Update Rollup 1 • Windows XP Professional, Service Pack 2b No operating system updates have been applied to the factory image beyond the service packs. For your convenience, the I386 source directory for Microsoft Windows is on the system drive of your computer off the root directory, C:\I386.
VersaView Industrial Non-display Computers Before You Begin Before unpacking the product, inspect the shipping carton for damage. If damage is visible, immediately contact the shipper and request assistance. Otherwise, proceed with unpacking. Keep the original packing material in case you need to return the product for repair or transport it to another location. Use both the inner and outer packing cartons to provide adequate protection for a unit returned for service.
VersaView Industrial Non-display Computers 7 Required Tools These tools are required to rack- or machine-mount your computer: • #2 Phillips screwdriver • Drill motor and drill bit Mounting Clearances Review the product dimensions to make sure you allow adequate clearance on the sides and rear of the computer for ventilation and cable connections. You must also be able to remove the covers to install or remove peripheral components.
VersaView Industrial Non-display Computers 92 [3.62] 2. Drill holes in the shelf that correspond to holes in the mounting brackets. • The 200R requires four holes. • The 700R requires eight holes. Dimensions are in mm (in.). 34.5 [1.36] VersaView 200R 192 [7.57] 260.00 (10.24) 50.00 (1.97) 24.00 (0.94) 233.00 (9.17) 213.00 (8.39) 50.00 (1.97) 3. Place the computer on the shelf and align the holes in the mounting brackets with the holes in the shelf. 4.
VersaView Industrial Non-display Computers 9 Mount the Computer on a Wall You can mount the VersaView 200R computer on a wall inside a machine by using mounting brackets. The brackets secure the computer to the wall. 1. Attach the two mounting brackets to the rear of the computer by using four of the provided, M3 x 12 mm panhead screws; torque to 0.678 Nm (6 lb-in). 2. Drill four holes in the wall that correspond to the holes in the mounting bracket. Dimensions are in mm (in.). 92.00 [3.62] 172.20 [6.
VersaView Industrial Non-display Computers Mount the Computer on a DIN Rail You can mount the VersaView 200R computer on a DIN rail. The DIN rail bracket mounts to the bottom or back of the computer. IMPORTANT Do not mount the computer on a DIN rail in high shock and vibration environments. 1. Fasten the DIN rail bracket on the bottom or back of the computer by using four, M3 x 5 mm panhead screws; torque to 0.678 Nm (6 lb-in). Rear Mount DIN Rail Bottom Mount DIN Rail 74.58 [2.
VersaView Industrial Non-display Computers 11 Mount the Computer on a Rack You can install the VersaView 1400R computer in a rack cabinet that conforms to EIA standards for equipment with 483 mm (19 in.) wide panels. The cabinet must accommodate the computer’s 4U height and depth, and also provide rear clearance for cables and air flow. A cabinet with a depth of 610 mm (24 in.) is sufficient. The computer must be supported by rack slides or fastened to a shelf.
VersaView Industrial Non-display Computers VESA Mount the Computer You can VESA mount the VersaView 200R computer to any of the VersaView industrial monitors or other surface by using the VESA mounting bracket provided. 1. Orient and attach the VESA mounting bracket to the four, 100 mm VESA holes that will be used to mount the computer. Use four, M4 x 8 mm flathead screws with four, M4 x 3 mm nuts. If attaching the bracket to the back of a VersaView monitor, the nuts are not needed.
VersaView Industrial Non-display Computers 13 The illustration shows the VersaView 200R computer VESA mounted to the back of a VersaView 1700M monitor.
VersaView Industrial Non-display Computers Product Dimensions Product dimensions for each model of the computer are given in mm (in). VersaView 200R Computer 150.00 (5.91) 115.40 (4.54) 172.20 (6.78) VersaView 700R Computer 431.30 (16.98) 253.00 (9.96) 258.00 (10.16) 192.00 (7.
VersaView Industrial Non-display Computers 15 560.00 (22.05) 517.00 20.34) 508.00 (20.00) VersaView 1400R Computer 176.00 (6.93) 165.10 (6.50) 101.60 (4.00) 481.80 (18.97) 465.00 (18.31) 431.00 (16.
VersaView Industrial Non-display Computers Connect the Keyboard and Mouse You can plug either a keyboard or mouse into the PS/2 port on the computer. You can connect both devices by using the PS/2 adapter cable that is shipped with the computer.
VersaView Industrial Non-display Computers 17 Connect Power The power connection for the computers varies by model. • The VersaView 200R computer connects to either a 120/240V ac or 9…36V dc power source, depending on the model. • The VersaView 700R and 1400R computers connect to a 120/240V ac power source. Connect ac Power Computers with an ac power input use a standard IEC 320 power cord. The power supply input accepts 120/240V ac and is autoranging.
VersaView Industrial Non-display Computers Connect dc Power The power supply on the VersaView 200R computer has a dc input terminal block for connecting to a 9…36V dc power source. ATTENTION Connect the dc ground connection to a power source with an earth ground to prevent electrical shock. Failure to follow this warning could result in electrical shock. The computer circuit should have its own disconnect.
VersaView Industrial Non-display Computers 19 Connect to the Network The computer connects to the Ethernet network by using CAT5 or CAT5E twisted-pair Ethernet cabling with RJ45 connectors. IMPORTANT To prevent performance degradation of Ethernet communication, do not subject the computer or cables to extreme radiated or conducted high-frequency noise. Proper cable routing and power conditioning is required for reliable Ethernet communication in industrial environments.
VersaView Industrial Non-display Computers Specifications VersaView Industrial Non-display Computers Attribute Value Electrical Input voltage, ac 90…264V ac, autoranging Line frequency 47…63 Hz Power consumption, ac 200R 700R 1400R 30 W (0.5 A @ 100V rms, 0.28 @ 240V rms) 130V A (1.3 A @ 100V rms, 0.54 A @ 240V rms) 150V A (1.5 A @ 100V rms, 0.63 A @ 240V rms) Input voltage, dc 200R 9…36V ac, autoranging Power consumption, dc 200R 30 W (0.84 A @ 36V dc, 3.
VersaView Industrial Non-display Computers 21 Certification (1) c-UL-us UL 60950 recognized component, c-UL 950 recognized component, or UL/c-UL listed when marked CE Marked for all applicable directives EMC 89/336/EEC LVD 73/23/EEC RoHS compliant C-Tick (1) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions See http://ab.com for declarations of conformity, certificates, and other certification details.
VersaView Industrial Non-display Computers Publication 6155R-IN001I-EN-P - July 2007
VersaView Industrial Non-display Computers 23 Publication 6155R-IN001I-EN-P - July 2007
Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools.