Industrial 14” CRT Monitors (Bulletin Number 6156) Product Data and Installation Instructions
Industrial Computer with Integrated Display and Keypad & % $' #" ! "& #"& "&' ' #" "&'%( ' #"& #"" ' " #) % # & +$ $' #" + # % *' " % & #( & % " $' #" #"" ' " '# #!$(' % #"'%# & " " '#%& "' " " %#( & ##' " $ ' #"& Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.
Industrial 14" CRT Monitors Description Bulletin 6156 Industrial 14 in. CRT Monitors are general purpose monitors suitable for a wide range of industrial computing applications. Package Contents The Bulletin 6156 Industrial Monitor is shipped with the following items: • 6156 Industrial 14 in. Color CRT Monitor with configurable options for keypads, touchscreen, and video interface Monitors without the touchscreen option have a polycarbonate screen protector.
Industrial 14” CRT Monitors Dimensions Note: Be sure to allow at least 76.2 mm (3.0 in.) depth clearance for cable connections and air flow. Figure 1 Bulletin 6156 Industrial Monitor (With Keypads) Physical Dimensions 130680 Publication 6156-2.
Industrial 14” CRT Monitors 5 Figure 2 Bulletin 6156 Industrial Monitor (Without Keypads) Physical Dimensions 335.3 (13.20) SEE NOTE 20.3 (0.80) 309 (12.20) 269.2 (10.60) 216.4 (8.52) 291.3 11.47) 482.6 (19.00) 412.8 (16.25) 17.5 (0.69) Note: Be sure to allow at least 76.2 mm (3.0 in.) depth clearance for cable connections and air flow. 130681 Publication 6156-2.
Industrial 14” CRT Monitors Installation Instructions Environmental Considerations The 6156 Industrial Monitor requires a minimum free air space of 76.2 mm (3 in.) behind and 50.8 mm (2 in.) above and below for proper cooling. Allen-Bradley Industrial Monitors have been designed to function without cooling fans. Therefore, maintenance of fan filters and access to them need not be a concern.
Industrial 14” CRT Monitors 7 5. Insert the monitor in the panel cutout from the front of the panel. Be careful not to damage the threaded mounting studs as you position the monitor. 6. Secure the unit with the locknuts and washers provided. Tighten evenly to 25 inch-pounds of torque. Important: To assure a proper seal, be sure to install a washer and nut on each of the 14 mounting studs.
Industrial 14” CRT Monitors Figure 3 Bulletin 6156 Panel Cutout Dimensions (3.16) 447.7 8 Publication 6156-2.
Industrial 14” CRT Monitors Connecting AC Power 9 The Bulletin 6156 Industrial Monitor requires a single phase power supply providing 100 to 250V AC at 50 to 60 Hz. Power must be available at a grounded three-pin outlet located nearby. Whenever possible, connect the monitor to the same AC source that supplies the computer. To connect AC power to the monitor: 1. Turn off the main switch or breaker. 2. Use the GND point on the rear panel of the monitor to establish a chassis to earth ground connection.
Industrial 14” CRT Monitors Video Cables The Bulletin 6156 Industrial Monitor can be configured with various industrial grade video cables. The standard HD15 cable is equipped with a conventional HD15 connector at each end.
Industrial 14” CRT Monitors 11 Table B Coaxial Cable Construction Signal Description Monitor DB-13C3 A1 Center Pin A1 Outer A2 Center Pin A2 Outer A3 Center Pin A3 Outer Green Video 2 Green Video Ground 7 Red Video 1 Red Video Ground 6 Blue Video 3 Blue Video Ground 1, 2, 3, 6, 7, 8 Computer HD15 Not Connected 8 4, 9, 11, 12, 15 4 Vertical Sync 14 5 Horizontal Sync Ground 10 9 Vertical Sync Ground 5 10 Horizontal Sync 13 Another low noise video interface is the Differential BN
Industrial 14” CRT Monitors Figure 6 Numeric Keypad Table D Numeric Keypad Functions and Scan Codes Keypad Legend Corresponding AT Key Scan Code (Hex) Keypad Legend Corresponding AT Key Scan Code (Hex) 7 Number Pad 7 / Home 47 TAB Main Pad Tab 0F 8 Number Pad 8 / Up Arrow 48 ENTER Main Pad Enter 1C 9 Number Pad 9 / Pg Up 49 SPACE Main Pad Space Bar 20 – Number Pad – 4A SHIFT Main Pad Left Shift 2A 4 Number Pad 4 / Left Arrow 4B CTRL Main Pad Left Control 1D 5 Numbe
Industrial 14” CRT Monitors 13 Keyboard Extender Cables For units configured with the keypad option, a keyboard extender cable is available in various lengths.
Industrial 14” CRT Monitors Connecting to a Computer Connect the Industrial Monitor to a computer with a video cable. A keyboard extender cable is required for monitors equipped with the keypad option. A touchscreen serial cable is required for monitors equipped with the touchscreen option. To connect your monitor to a computer: 1. Plan the route for the cables through the enclosure and confirm that the cables you have ordered are long enough for the routing you have chosen.
Industrial 14” CRT Monitors 15 2. If you are using a standard HD15 video cable with the Industrial Monitor, connect either end of the cable to the 15-pin video input connector. See the rear panel drawing (Figure 7) to locate the connector. Tighten the captive screws on the cable connector to secure it. Or If you are using the optional DB-13C3 video interface, connect the large end of the video cable to the large video input connector. Tighten the captive screws on the cable connector to secure it.
Industrial 14” CRT Monitors 5. For monitors configured with the touchscreen option, connect one end of the serial touchscreen cable to the connector labeled ”AUX1” on the rear panel of the monitor. Tighten the captive screws to secure it. 6. Route and secure the cables. In cases where the cable crosses a door hinge, be sure to leave enough excess cable for a loose fit in all door positions.
Industrial 14” CRT Monitors Controls & Indicators 17 The following is a summary of the controls and indicators on the Bulletin 6156 Industrial Monitor. Figure 8 Controls and Indicators Brightness and Contrast Manual Degauss Raster Rotation Power Indicator Size and Position Power Indicator The presence of AC power at the Bulletin 6156 Industrial Monitor is indicated by a green LED on the rear panel.
Industrial 14” CRT Monitors The monitor is factory preset and normally requires no manual adjustment for vertical or horizontal alignment. However, four screwdriver adjustable size and position controls are provided to permit adjustment if it should ever become necessary. Adjust controls using a non–metallic insulated 1/8” (3mm) flat screwdriver passed through the hole(s) of the rear cover. With a suitable full screen image on display, adjust the Vertical Size for a height of 7.
Industrial 14” CRT Monitors 19 Note: This effect is different from the effect of magnetism on the shadow mask, which takes the form of color impurity and is corrected by the degaussing system described previously. Before making any adjustment, display a full screen image and check for rotation (top or bottom edge of the image out of parallel with the corresponding edge of the panel). If adjustment is necessary, 1. Loosen the lock nut on the control shaft. 2.
Industrial 14” CRT Monitors Fuse replacement Bulletin 6156 Industrial Monitors are equipped with an AC line fuse, which is accessible from the rear panel. To replace the fuse: 1. Remove AC power by disconnecting the AC line cord. 2. Use a flat blade screwdriver to unscrew the cap on the fuse holder. 3. Remove the cap and fuse. 4. Replace the fuse with a 5ST Slo-Blo type rated at 2.5A, 250VAC. 5. Secure the fuse holder cap with the screwdriver. 6. Restore AC power.
Industrial 14” CRT Monitors Troubleshooting The following table can help you identify the potential cause of problems you may encounter while using the 6156 Industrial Monitor. ! Symptom No Video 21 Possible Cause ATTENTION: When attempting to correct a problem, do not change any adjustments located on the monitor chassis’ left side (as viewed from the front of the monitor). These adjustments are for factory trained personnel using special test and alignment equipment.
Industrial 14” CRT Monitors Specifications Display Type CRT, Color CRT Size 14” Diagonal Nominal Display Area 10.0” Horizontal x 7.5” Vertical (254mm x 191mm) Resolution 640 x 480 to 1024 x 768, autosync Dot Pitch 0.28mm Luminance 40 ft–Lamberts (137 cd/m2 with full screen white flood) Horizontal Scan Rate 30 kHz to 56 kHz Vertical Scan Rate 40 Hz to 90 Hz Video Bandwidth 75 MHz Video Inputs RGB Analog, RS-343A (0.
Industrial 14” CRT Monitors Specifications (Continued) 23 Environmental Operating Temperature 0°C to +50°C Storage Temperature –30°C to +70°C Relative Humidity 5% to 95% (non–condensing) Operating Shock 15g (1/2 sine, 11 msec duration) Non–operating Shock 30g (1/2 sine, 11 msec duration) Operating Vibration 0.01 in. p-p 5-17 Hz sine, 1.5g peak, 17-640 Hz sine Non–operating Vibration 0.2 in. p-p 5-16 Hz sine, 2.5g peak, 16-640 Hz sine Physical Faceplate Overall Height 12.
IBM is a registered trademark of International Business Machines Corporation VGA is a trademark of International Business Machines Corporation. PC AT is a trademark of International Business Machines Corporation Microsoft is a registered trademark of Microsoft. Microsoft Windows is a trademark of Microsoft.