Owner`s manual

r
AR-3000 RS-232C Reference -18
Phrase Settings
< SU (phrase Set Up for AR-2000)
Function: Phrase settings
Syntax: stxSU: **** , *********** , *** , **S* , * , **M**S , * , **M**S , *** , * ;
a b c d e f g h I j
a Phrase number
b Phrase name (up to 12 characters)
c Playback Volume (10 - 100)
d Delay Time (0S0 - 59S9)
e Repeat Playback
0 OFF
1 ON
f Repeat interval (0M0S - 59M59S)
g Control Output
0 OFF
1 ON
h Offset time of control output (0M0S - 59M59S)
i Tempo (5 - 260)
j Reserved (Only '0')
Example) SU:A001,ABCDEFGHIJK,100,10S5,1,5M0S,1,5M10S,120,0;
For phrase number A001, this sets as follows; Phrase name ABCDEFGHIJK,
Playback Volume 100%, Delay Time 10.5 seconds, Repeat Playback ON, Repeat
interval 5 minutes,
Control Output ON, Offset time of control output 5min10sec, and Tempo 120.
Note: Be sure to specify an already recorded phrase as the phrase number.
> PN (Phrase Name set up for AR-3000)
Function: Phrase Name settings
Syntaxs stxPN: **** , ***********;
a b
a Phrase number
b Phrase name (up to 12 characters)
> PR (Phrase Repeat set up for AR-3000)
Function: Phrase Repeat settings
Syntax: stxPR: **** , *,**,**M**S;
a b c d
a Phrase number
b Repeat
0 OFF
1 ON
c The number of repetitons
0 ENDLESS
1 1
|
99 99
d Repeat interval (0M0S - 59M59S)