Owner`s manual

2
TD-10 (
TDW-1 V-Cymbal Contro
l)
TD-10 (TDW-1)
TD-10 (Non expanded)
TD-8
(*2)
TD-6
TD-7
(*3, *4)
TD-5
SPD-20
HPD-15
(*4)
Trigger Type
RdA
Sensitivity
8
Threshold
4
Curve
Linear
Scan Time (*1)
1.0
Retrigger Cancel
(*1)
10
Mask Time (*1)
8
Xtalk Cancel (*1)
50
Mount Type (*1)
CymMount
Trigger Type
P7B
Sensitivity
8
Threshold
4
Curve
Linear
Scan Time (*1)
1.8
Retrigger Cancel
(*1)
5
Mask Time (*1)
8
Xtalk Cancel (*1)
40
Mount Type (*1)
CymMount
Trigger Type
Pd7
Sensitivity
5
Threshold
3
Curve
Linear
Scan Time (*1)
1.5
Retrigger Cancel
(*1)
5
Mask Time (*1)
8
Xtalk Cancel (*1)
40
TRIGGER TYPE
CY1/PD7
SENSITIVITY
(*1)
10
THRESHOLD
(*1)
4
CURVE
(*1)
LINEAR
SCAN TIME
(*1)
2.5
RETRIG CANCEL
(*1)
8
MASK TIME
(*1)
8
XTALK CANCEL
(*1)
50
TrigType
CY Type
Sensitivity
(*1)
10
Threshold
(*1)
4
TrigCurve
(*1)
LINEAR
Xtalk Cancel
(*1)
50
Scan Time
(*1)
2.5ms
Retrig Cancel
(*1)
8
Mask Time
(*1)
8ms
Cross Talk Group
1
Velocity Curve Norm3
Choke Off
Max Dyna 5
MIn Dyna 1
Min Velo 1
Mask Time 0
Threshold 1
Trigger Type P1
Sensitivity 8
Threshold 2
Curve Lnr
Scan Time 2.5
Retrigger Cancel 3
Mask Time 8
Crosstalk Cancel 50
Trig Sens 10
Trig Threshold 0
Trig Type Pd7
Trig Curve 0
Scan Time 2.5
Retrig Cancel 3
Mask Time 8
Crosstalk Cancel 30
Input Mode HD/RM
Trig Type PD-9
Trig Sens 10
Curve Linear
Threshold 2
Scan Time 1ms
Retrig Cancel 2
Mask Time 4ms
X-Talk Rate 40%
Recommended settings for the trigger parameters when using the CY-12R/C with various percussion
sound modules.
Bow shots, edge shots, bell shots and choking techniques are possible with the CY-12R/C (p. 6).
If you find it difficult to get bell shots to sound, try adjusting the “Scan Time.”
The trigger parameters should be adjusted as necessary to match the actual state of your configuration, and the
environment in which it is being used.
Recommended Settings for the Percussion Sound Module
*1: You need to set each trigger parameter after setting the trigger type.
*2: Notice Regarding TD-8 Upgrade
As of October 2001, CY1 has been added as a trigger type selection. Selecting CY1 automatically sets the other trigger
parameters to the recommended values, allowing you to make the settings for the CY-12R/C simply and easily.
You can use the CY-12R/C even with previous TD-8 versions by selecting PD7, then manually setting the other trigger
parameters to the recommended values (as shown in the above list).
For more information about the TD-8 upgrade, consult with your retailer, the nearest Roland Service Center, or an
authorized Roland distributor, as listed on the Information page.
*3: Each trigger parameter can be set independently for the head-side and rim-side. Set to the same value for the head and
rim. Trigger parameters can be set individually for each patch.
*4: The TD-7 and the HPD-15 support the use of edge shots with the CY-12R/C, but they do not support choking techniques.