Owner`s manual

123
Chapter 7 Environment Configuration and
Chapter7
MIDI-Related Settings
* It is not possible to access these setting pages while a pattern
or song is playing back.
Using an external MIDI keyboard in
place of the keyboard pads
(REMOTE KEYBOARD)
An external MIDI keyboard can be used instead of the MC-
307s keyboard pads.
Procedure
1. Press the [SYSTEM] button, then the [F1 (SYS)] button.
The selection screen for system settings appears.
2. Press the [CURSOR (up)] button to access the screen for
items 14.
3. Press the [F4 (MIDI)] button.
4. Press [F1 (CMN)] button.
If the following screen is not displayed, use [F4 ( )] to
make it appear.
5. Use the [CURSOR (up/down)] buttons to move the
cursor to REMOTE KEYBOARD.
6. Specify a value using the [VALUE] dial or the [INC/
DEC] buttons.
Range: OFF, ON
This parameter is set to ON with the factory settings,
enabling patches in the part selected on the MC-307 to be
played back regardless of the transmission channels of
the external MIDI keyboard.
Set it to OFF to control the MC-307 from an external
sequencer, as a multi-timbre sound generator with eight
parts. Patches can be played back by part, according to
the channel used for sending MIDI data from the
external sequencer.
You should also turn this setting OFF if you want Note
messages that are received on the specified Arpeggio
Control Channel or the RPS Control Channel to control
arpeggios or RPS from an external device.
- Specifying the Channel That Will Control Arpeggios,
refer to Specifying the channel that will control
arpeggios (ARPEGGIO CTRL CH) (p. 124).
- Specifying the Channel That Will Control RPS, refer to
Specifying the channel that will control RPS (RPS CTRL
CH) (p. 124).
Parameter Type: Backup parameters
Identifying devices of the same model
(DEVICE ID)
This function is use to set up a device ID number of a system-
exclusive message on the MC-307.
A system exclusive message can only be received if the
device number included in the message matches the device
ID number set up on the receiving MIDI equipment.
Using this function enables different System Exclusive
messages to be received by more than one MC-307 unit at the
same time.
Procedure
1. Press the [SYSTEM] button, then the [F1 (SYS)] button.
The selection screen for system settings appears.
2. Press the [CURSOR (up)] button to access the screen for
items 14.
3. Press the [F4 (MIDI)] button.
4. Press [F1 (CMN)] button.
If the following screen is not displayed, use [F3 ( )][F4
( )] to make it appear.
5. Use the [CURSOR (up/down)] buttons to move the
cursor to DEVICE ID.
6. Specify a value using the [VALUE] dial or the [INC/
DEC] buttons.
Range: 1732
Parameter Type: Backup parameters
* The bulk dump message (one of the System Exclusive
messages) is sent with the device ID number set up in the
above procedure.
Re-transmitting messages received at
MIDI IN from MIDI OUT (THRU)
When this function is ON, MIDI messages received at the
MIDI IN connector will be re-transmitted from MIDI OUT
without change.
(The MIDI OUT connector can be used as the MIDI THRU
connector.)
Procedure
1. Press the [SYSTEM] button, then the [F1 (SYS)] button.
The selection screen for system settings appears.