Owner`s manual

Sys Exclusive (System Exclusive)
These are MIDI messages unique to the MC-505. If the
entire message cannot be shown on one line, a Ò Ó
will appear at the right edge of the display.
You can press PAGE [<] [>] to scroll the display
screen. This is used only in the MUTE CTRL part.
fig.10-67
No Event
If there is no MIDI message at the current position, the
following display will appear.
fig.10-68
Modifying the Value of Musical
Data (Change Event)
1. In the Microscope page, rotate the [VALUE]
dial to select the musical data that you
wish to change.
2. Press PAGE [>].
The cursor will appear below parameter values that
can be modified.
fig.10-69
3. Use [INC] [DEC] or the [VALUE] dial to modi-
fy the value.
4. Press [ENTER].
The normal display will reappear.
For messages that have more than one parameter
value that can be modified (such as Notes, Control
Changes, Polyphonic Aftertouch, etc.), use [ENTER] or
PAGE [<] [>] to move the cursor.
fig.10-70
Modifying system exclusive data
System exclusive messages begin with F0, and end
with F7. Data values are shown in hexadecimal nota-
tion (00Ð7F).
1. In the Microscope page, rotate the [VALUE]
dial to select the system exclusive message
that you wish to modify.
2. Press PAGE [>].
The system exclusive input page will appear, and the
cursor will appear in the display.
fig.10-71
3. Press PAGE [<] [>] or [ENTER] to move the
cursor to the location that you wish to
modify.
4. Use [INC] [DEC] or the [VALUE] dial to modi-
fy the value.
At this time, you can use the keyboard pads to enter a
hexadecimal number. The hexadecimal digit entered
by each pad is as follows.
fig.10-72
5. Move the cursor to the F7 location and
press [ENTER], and the modified settings
will be finalized.
When the settings have been finalized, you will return
to the normal Microscope display.
* It is not possible to change the F0 that begins the message
or the F7 that ends it.
* To add data, use the keyboard pads to input a value at the
F7 location.
* By pressing [UNDO/REDO] you can delete the data at
the cursor location.
To cancel the operation without changing the data,
press [EXIT].
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
About the checksum
When inputting a Roland Type IV exclusive message,
you must input a checksum immediately before the
F7. Since the MC-505 will calculate the checksum auto-
matically, there is no need for you to modify the
checksum value. When you input a new exclusive
message, you can simply input an arbitrary number
immediately before F7, and the MC-505 will calculate
the correct number automatically.
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
1234567890ABCDEF
PAGE
PAGE
PAGE
Chapter 10. Recording Patterns
142
0