ting if you wish to shift the data toward the end.
If this is set to Ò0Ó the data will not be shifted.
5. Press [ENTER].
The display will indicate the type of musical data that
will be shifted.
6. Select the type of musical data that you
wish to shift.
fig.11-34
Range:
ALL: All musical data
NOTE: Note
PC: Program change
CC: Control change
BEND: Pitch bend
P-AFT: Polyphonic aftertouch
C-AFT: Channel aftertouch
SYS-EX: System exclusive
TEMPO: Tempo
MUTE: Mute
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
NOTE is selected as the type of musical data, and if
you wish to shift only a specific range of notes, use the
keyboard pads to specify the desired range. If you do
not specify a range of notes, all notes will be shifted.
●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●●
7. Press [ENTER].
The confirmation screen will appear in the display.
fig.11-35
8. Press [ENTER] once again.
The Shift Clock operation will be carried out, and the
normal display will reappear.
Thinning Out Unneeded Data
(Data Thin)
Since messages such as pitch bend or control change
use continuously changing values, they can occupy an
unexpectedly large amount of memory. The Data Thin
operation lets you thin out such data in a way that will
not affect the audible result, yet will reduce the
amount of data.
* It is not possible to specify the range of measures affected
by this operation.
fig.11-36TEXT
1. Select the pattern in which you wish to thin
data.
2. Hold down [EDIT] and press keyboard pad
[9].
The Data Thin setting page will appear in the display.
fig.11-37
2. Select the part whose data will be thinned.
* You may select more than one part.
3. Specify the amount of data to be thinned.
Range: 0Ð99
Higher settings will cause more data to be thinned.
If the setting is Ò0,Ó the data will not be thinned.
4. Press [ENTER].
The display will indicate the type of musical data that
is to be thinned.
5. Select the type of musical data that you
wish to thin.
fig.11-38
Range:
ALL: All of the following musical data
CC: Control change
BEND: Pitch bend
P-AFT: Polyphonic aftertouch
C-AFT: Channel aftertouch
6. Press [ENTER].
The confirmation screen will appear in the display.
fig.11-39
7. Press [ENTER] once again.
The Data Thin operation will be carried out, and the
normal display will reappear.
REALTIME ERASE
EDIT
9
Value Value
Time Time
Thin out
the data
Chapter 11. Editing Patterns (Pattern Edit)
152
1