Owner`s manual

If an incorrect operation has been performed or if pro-
cessing could not be carried out as specified, an error
message will appear. Refer to this list and take the
appropriate action.
fig.17-1
¥ There is a problem with the MIDI cable connec-
tions.
Make sure that MIDI cables have not been pulled
out or broken (Quick Start; p. 3).
fig.17-2
¥ More MIDI messages were received at once than
the MC-505 was able to process.
Reduce the amount of MIDI messages that are
being transmitted to the MC-505.
fig.17-3
¥ More recording data was received at once than the
MC-505 was able to process.
Reduce the amount of recording data that is being
transmitted to the MC-505.
fig.17-4
¥ The checksum value of the received system exclu-
sive message is incorrect.
Correct the checksum value.
fig.17-5
¥ Since the maximum number of notes that can be
recorded in a single pattern has been reached, fur-
ther pattern recording is not possible.
Delete unneeded data from the pattern that you are
recording (p. 147).
fig.17-6
¥ Since the maximum number of patterns that can
be registered in a single song has been reached,
further song recording is not possible.
A maximum of 50 patterns can be registered in a
single song. No further patterns can be registered.
fig.17-16-1
¥ Recording is not possible because Megamix mode
is selected.
Write the pattern, and then record.
fig.17-7
¥ Since there is insufficient user memory, the pat-
tern cannot be saved.
Either initialize an unneeded pattern, or save the
data to a memory card.
fig.17-8
¥ Since there is insufficient card memory capacity,
the pattern cannot be saved.
Either initialize an unneeded pattern, or save the
data to internal memory.
fig.17-8
¥ Since a different time signature is set for the copy
source and copy destination patterns, the pattern
copy is not possible.
The pattern copy operation can only be used for
patterns with the same time signature.
fig.17-9
Error Message List