Technical data

Manual
Double Sheet Detector R1000 series E20
B0046991 / Rev. 1.6
Start-up
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
101
7.3 Configuration menu
7.3.1 Main menu structure
Button
MENU
Config.
Review
change
(password)
System Parameter
7.7
General system configuration
Program Parameter
7.6
Parameter of the respective measurement programs
Data backup
7.8
Backup of the data stored in the system
via RS232-Interface
Fig. 37: Main structure of configuration menu
7.3.2 Sub structure “Program parameter”
Program no. (1-255)
up% (100-150%) and absolute
1 / 2 / 3 / 4 / 1+2 / 1+3 / 1+4 / 2+3 / 2+4 / 3+4 /
1+2+3 / 1+2+4 / 1+3+4 / 2+3+4 / 1+2+3+4
Sensor number
low% (0 - 99%) and absolute
P30:
Nominal thickness
P36:
P42:
P42A:
P75:
P75V:
Zero adjust
off
on separate (only the sensors selected in the menu)
Sensor 1 on / off
Sensor 2 on / off
Sensor 3 on / off
Sensor 4 on / off
Teach-In
on separate (only the sensors selected in the menu)
Sensor 1 on / off
Sensor 2 on / off
Sensor 3 on / off
Sensor 4 on / off
off
Program Parameter
0,03 - 2,5 mm (.001 - .098 inch)
0,03 - 2,5 mm (.001 - .098 inch)
0,03 - 4,0 mm (.001 - .16 inch)
0,03 - 4,0 mm (.001 - .16 inch)
0,03 - 6,0 mm (.001 - .24 inch)
0,03 - 6,0 mm (.001 - .24 inch)
Fig. 38: Sub structure „Program parameter“