Technical data

Manual
Double Sheet Detector R1000 series E20
Start-up
B0046991 / Rev. 1.6
106
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Program parameter 4: Setting the percentage threshold of the upper limit value.
Fig. 46: Adjusting the upper limit
Value range: between 100% and 150%, with simultaneously displaying the absolute limit value.
The maximal settable absolute limit depends on the sensor:
P42, P42A: 5 mm (.197in.)
P30, P36: 3 mm (.118in.)
P75: 6.8 mm (.268in.)
P75V: 9.2 mm (.362in.)
Program parameter 5: Setting the percentage threshold of the lower limit value.
Fig. 47: Adjusting the lower limit
Value range: between 0% and 99%, with simultaneously displaying the absolute limit value.
Program parameter 6: Zero adjust
The Zero adjust pr ocedure mus t be performed at commissioni ng and after h aving exchang ed a sensor.
Attention Before performing a Zero adjust procedure, verify in any case that
no sheet is in front of the sensor (the sensors).
Fig. 48: Status of Zero adjust
For performing a zero adjust press the ENTER key (if no zero adjust is present or for repeating)
Possible choices (only for 4P versions):
separate: All connected sensors must be zero adjusted individually
(each sensor is addressed individually for “on“ or off“).
common: All sensors are zero adjusted at the same time.
program par. 4
up 120% 1.35mm
program par. 5
low: 80% 0.45mm
program par. 6
zero adjust: off