Technical data

Manual
Double Sheet Detector R1000 series E20
Start-up
B0046991 / Rev. 1.6
108
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Then press the ENTER key.
The Teach-In measurement value is then displayed:
Fig. 53: Teach-in measurement value
This measured value can be accepted or changed, e.g. to calibrate the control unit.
The teach-in procedure is now completed (for a 1P system).
Attention For a 4P system with sequential measurement the entire teach-in
procedure for all sensors is performed in the selected sequence. For
sensor selection A/B the teach-in for the selected sensor is then
competed. However, if all sensors should be taught, then the teach-in
of the other sensors must be repeated separately.
Description of the Teach-in procedure:
Locally at the control unit With PLC (parallel or fieldbus)
With system parameter 3: mm or inch %mm or inch mm or inch %mm or inch
Step 1: attach sheet to
sensor and initiate
teach-in
measured value is
displayed
measured value is
displayed
– –
Step 2: Calibration
change displayed
value to actual
value (e.g. as
measured with a
micrometer)
Max. possible
correction see I.
displayed value is
transferred as
nominal thickness
(100%) to the
program
Max. possible
correction see II.
measured thickness
is changed to
nominal thickness
Max. possible
correction see III.
measured thickness
is transferred as
nominal thickness
(100%) to the
program
Max. possible
correction see II.
I. Maximum possible correction is double the displayed value, however, not more than 133% of the nominal
thickness and not more than the max. measurable thickness (depends on sensor size), under gauge correction is
max. 75% of the displayed value, however not less than 50% of the nominal dimension
II. Unlimited, displayed value must be larger than 0.05 mm and smaller than the max. measurable thickness
(depends on sensor size)
III. +100% / -25% related to the measured thickness. If this correction range is not sufficient, in order to reach the
nominal dimension, an error message is generated
The Teach-In affects only the selected program.
Pos: 59 /Doppel blech/Geräte/E2 0/7 Inbetriebna hme/Param eter (System-) @ 1\mod_11924 48722578_50 1.doc @ 4928 @ 2 @ 1
program par. 7
TI val.: 0.97mm