Technical data

Manual
Double Sheet Detector R1000 series E20
B0046991 / Rev. 1.6
Start-up
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
113
System parameter 13: Selecting the speed of measurement.
Fig.. 66: Selecting the speed of measurement
Possible choices:
normal: Here the system reaction time depends on the measured sheet thickness.
The maximum can be inferred from the diagrams in chapter "2.4"
fast: Here the system is enabled to detect double sheets before the "normal" end
of the measurement.
Advantage: The system reaction time is shorter and depending on the
adjusted nominal thickness as well as the upper limit value.
Disadvantage: In case of measuring results larger than the double sheet
threshold, a double sheet signal is issued but not the actual measurement
values.
System parameter: Indication of versions of Hardware and Software.
Fig.. 67: Indication of versions
Meaning:
E20 Type of system (4) 4 sensors connected
4P Version with 4 Sensors SW Software version
C Version C HW Hardware version
O Version Opto coupler
Pos: 60 /Doppel blech/Geräte/E2 0 Bus/7 Inbetr iebnahme/Dat ensicherung (RS 232) @ 0\m od_11732779 07015_501.doc @ 3239 @ 2 @ 1
7.8 Data storage via serial RS232-interface
For better prevention from loss of data, a data backup procedure is available for the system
configuration and the parameter sets. This is made via the RS232-interface (not in B- versions).
The secured data can be transferred to spare units in case of exchange after a failure.
The data backup is accomplished with the RPP software available from ROLAND.
The data backup procedure can be selected in the menu configuration. The following menu is
displayed during the data backup.
Fig. 68: Status of data backup
Pos: 61 /Kompo nenten allge mein/Leerseite @ 0\mod_11652 23317234_501. doc @ 2343 @ @ 1
system param. 13
measurement:fast
HW.:E20-4P-C-0(4)
SW:01 HW:01
Parameter backup
active