2.5 Sensor cables
Suitable cable types:
Oilflex FD810CY 2 x 1mm
2
Unitronic FDCP (TP) plus 1 x 2 x 1mm
2
(UL / CSA)
ROLAND ELECTRONIC uses according to standard the oilflex FD810CY 2 x 1mm
2
cable.
Both cables are oil-proof and suitable for drag chains
- Bending radius fix use 31 mm
- Bending radius flexible use 58 mm
Cable marking:
for P30GS and P42AGS:
CPM12S-G (straight receptacle at the sensor)
CPM12S-W (right angle receptacle at the sensor)
for P36GS, P42GS, P75GS, P75VGS,
CPS-GOIL (straight receptacle at the sensor)
CPS-WOIL (right angle receptacle at the sensor)
The cables are equipped with quick disconnect plug at the sensor side and with bootlace ferrules at
the control unit side.
Note The sensor cable is an active component of the sensor technology. The
technical data of the sensors is valid only if the cable specification is met. A
shielded 2 x 1 mm² cable must be used. The cable length can be to up to
50 m. Following the rule "the shorter the better" generally leads to better