Technical data
Manual
Double Sheet Detector R1000 series E20
B0046991 / Rev. 1.6
Technical data
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
23
Cable shields must be connected according to the wiring diagram (For details refer to chapter 5.4)
and should have no additional connections.
Note Damaged cable isolation can cause further (unwanted) electrical
connections.
Instruction: Leading a cable through EMC gland
• Remove outer PVC sheath and shield but leave enough length for sheath and leads.
• Circular cut of outer PVC sheath after about 20 mm, but do not remove
• Move cable through the gland
• Remove outer sheath
• Pull cable back until the shield and the contact springs inside the PG-gland connect.
• Close PG-gland
20mm
Kabelabschirmung
Cable shield
Fig. 8: Connecting cable to PC-gland