Technical data

Manual
Double Sheet Detector R1000 series E20
Technical data
B0046991 / Rev. 1.6
24
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
2.5.1 Sensor cables for direct connection of sensor
2.5.1.1 Cable CPM12S for sensors P30GS and P42AGS
1
2
4 3
Ø 20
55
Ø 20
54
31
33
OILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CSA)]
OILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CSA)]
Cable socket
to sensor / to cable extension
Bootlace ferrules
to control unit
1)
View contact side
Receptacle contact
1)
1
black (1) [white]
2
black (2) [brown]
3 N.C.
4 N.C.
5
blank (Shield)
Right angle cable socket (optional)
black (1) [white]
black (2) [brown]
black (1) [white]
black (2) [brown]
Fig. 9: Sensor cable CPM12S
to Sensor to control unit
Cable socket Bootlace ferrules
2
3
4
P30GS
P42AGS
1
2
3
4
5
5
C
A black (1) [white]
B black (2) [brown]
C blank (Shield)
Cable types for sensors P30GS and P42AGS (order data):
CPM12S-G (straight receptacle at the sensor)
CPM12S-W (right angle receptacle at the sensor)
The standard length is 5 meter. Cable length up to 50 meter made to order, longer cables please
enquire.
Note In particular with larger lengths the sensor cable should not be placed
directly adjacent to cables with large noise potential.
The cable is drag cable suitable and oil resistant.
Cable type:
Oilflex FD810CY 2 x 1mm
2
Unitronic FDCP (TP) plus 1 x 2 x 1mm
2
(UL / CSA)