Technical data

Manual
Double Sheet Detector R1000 series E20
Technical data
B0046991 / Rev. 1.6
26
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
2.5.2 Sensor cable extensions
A sensor cable extension can be relatively easy made. For this a CPM12S-G cable is always
needed. In addition, depending on the sensor, either the following cables SM12CPM12S-
GG/SM12CPM12S-GW for P30GS and P42AGS or SM12CPS-GG/SM12CPS-GW for P36GS,
P42GS, P75GS and P75VGS
2.5.2.1 Sensor cable extension SM12CPM12S for sensors P30GS and P42AGS
1
2
4 3
Ø 20
55
Ø 20
54
31
33
OILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CSA)]
OILFLEX FD810CY 2 x 1 mm²
[Unitronic FDCP (TP) plus 1 x 2 x 1 mm² (UL / CSA)]
5
1
2
43
Ø 20
62
Cable socket
to sensor
Cable plug
to cable extension
Plug contacts
1)
1)
View plug side
1
black (1) [white]
2
black (2) [brown]
3 N.C.
4 N.C.
5
blank (Shield)
1
black (1) [white]
2
black (2) [brown]
3 N.C.
4 N.C.
5
blank (Shield)
Right angle cable socket (optional)
socket contacts
1)
1)
View contact side
Fig. 11:Cable extension SM12CPM12S
to Sensor to cable extension
Cable socket Cable plug
2
3
4
5
1
2
3
4
5
C
A black (1) [white]
B black (2) [brown]
C blank (Shield)
Cable types for the P30GS and P42AGS sensor (order data):
SM12CPM12S-GG (straight receptacle at the sensor)
SM12CPM12S-GW (right angle receptacle at the sensor)
The standard length is 5 meter. Cable length up to 50 meter made to order, longer cables please
enquire.
Note In particular with larger lengths the sensor cable should not be placed
directly adjacent to cables with large noise potential.
The cable is drag cable suitable and oil resistant.
Cable type:
Oilflex FD810CY 2 x 1mm
2
Unitronic FDCP (TP) plus 1 x 2 x 1mm
2
(UL / CSA)