Technical data

Manual
Double Sheet Detector R1000 series E20
B0046991 / Rev. 1.6
Mounting
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
47
4.3.1 Checklist for Mounting of contacting Sensors
In the interest of longest lifetime and operational security the following items should be observed
when mounting contacting sensors and checked in regular intervals.
Point of attention Possible influences Checked
Cable type 1
Use only the recommended cable with
highest flexibility and durability.
2
Avoid any tension of the cable. Route
the cable with enough clearance.
Cable routing
3
Special care has to be taken to the route
of cable in front of sensor plug, if a
flexible sensor bracket is used. The
cable should never have a bend close to
the plug. Also the meander of the cable
has to be symmetrically to the axis of
the plug, see enclosed sketch.
Plug 4
Correctly tighten the arresting ring of the
plug. This avoids too strong wear of
contacts. If possible choose a sensor
with fixed cable instead.
5
Use a sensor bracket which is flexible
enough to let the sensor align also to
tilted sheets. This avoids unnecessary
wear of sensor contact surface.
Sensor mounting in the destacking tool
Noppen
Burls
Sensorkante
Sensor edge
Sauger
Suction cup
Sensor
6
Properly adjust sensor edge so that it
aligns with the rubber burls of the
suction cup. Do not allow excess end.
See enclosed sketch. This avoids
unnecessary wear of sensor contact
surface.
7
Properly adjust sensor mounting in
regard to the lifting suction cups of
tooling. Do not allow sensor suction cup
to excess lifting suction cups. This
avoids unnecessary wear of sensor
contact surface.
Pos: 30 /Doppel blech/Sensor en/Sensorhalteru ngen/Gefed erte Sensorhalteru ng SH42GS + SH75GS @ 1\ mod_121500 5512578_501. doc @ 6405 @ 34 @ 1