Technical data

Manual
Double Sheet Detector R1000 series E20
Mounting
B0046991 / Rev. 1.6
60
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
4.3.7 Incorrect mounting of the P sensors
The following illustration shows examples of incorrect installations of P-sensors.
Faulty!
The sensor does not touch the sheet.
Faulty!
The sensor does not sit perpendicular on the sheet, the sensor bracket is
apparently not suitable.
Faulty!
An air gap exists between the first and the second sheet.
The sensor is mounted in an unfavourable position.
Faulty!
An air gap exists between the first and the second sheet.
The second sheet clings to the first sheet, perhaps by stamping residuals.
Faulty!
Fault prone control in a bucket. An air gap exists between bended sheets.
Fig. 29: incorrect mounting of the p sensors